Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: CDI SRV. & MFG, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CDI SRV. & MFG, INC. in 2181 34TH WAY, LARGO, FL 33771 (NAICS 337127). OSHA activity number 341418267.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch CDI SRV. & MFG, INC. for free Get an email when a new federal OSHA severe-injury report for CDI SRV. & MFG, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2181 34TH WAY
City
LARGO
State
FL
ZIP
33771
Mailing
2181 34TH WAY, LARGO, FL 33771
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337127
Employees
5
Ownership type
A

6 citations on file for this inspection.

1910.213 D01

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 8, 2016
Penalty
Initial $4,276 · Current $2,566 Reduced
29 CFR 1910.213(d)(1): Circular handfed crosscut table saw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut:  a. On or about 04/21/2016, at the site - employees required to operate the table saws were exposed to amputation hazards, in that, the blade guards were removed from the Delta, table saw.
Recent events (2)
  • · I (S) $2565.6
  • · Z (S) $4276

1910.305 G02 II

Serious Gravity 1 1 instance 2 exposed
Issued
Aug 8, 2016
Abate by
Aug 25, 2016
Penalty
Initial $2,138 · Current $1,283 Reduced
29 CFR 1910.305(g)(2)(ii): Flexible cords were not used only in continuous lengths without splice or tap:  a. On or about 04/21/2016, at the site - employees were exposed to electrical contact hazards, in that, two extension or flexible cords had damage to the outer jacket or insulation.
Recent events (2)
  • · I (S) $1282.8
  • · Z (S) $2138

1910.305 G02 III

Serious Gravity 1 1 instance 2 exposed
Issued
Aug 8, 2016
Abate by
Aug 25, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:  a. On or about 12/30/2015, at the site - the casing was separating from the outlet box from a hanging flexible cord used to connect electric power tools, exposing employees to an electric contact hazard.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.22 A02

Other-than-serious 1 instance 4 exposed
Issued
Aug 8, 2016
Abate by
Aug 18, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.22(a)(2): Floor(s) of workroom(s) were not maintained in a clean and, so far as possible, a dry condition:  a. On or about 04/21/2016, at the site - the work area, particularly under the table saw, had a significant amount of saw dust.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.157 C01

Other-than-serious 1 instance 2 exposed
Issued
Aug 8, 2016
Abate by
Aug 18, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:  a. On or about 04/21/2016, at the site - the path to some fire extinguishers was obstructed by machinery or equipment.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.157 G01

Other-than-serious 1 instance 4 exposed
Issued
Aug 8, 2016
Abate by
Aug 18, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.157(g)(1): An educational program was not provided for all employees to familiarize them with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting:  a. On or about 04/21/2016, at the site - the employer did not provide fire extinguisher training to employee require to extinguish insipient stage fires.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View CDI SRV. & MFG, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341418267.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.