OSHA Inspection: CONSOLIDATED ELECTRIC DISTRIBUTORS, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of CONSOLIDATED ELECTRIC DISTRIBUTORS, INC. in 3535 N HOLLAND-SYLVANIA ROAD STE B, TOLEDO, OH 43615 (NAICS 453998). OSHA activity number 341418994.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Consolidated Electric Distributors, INC. — free Get an email when a new federal OSHA severe-injury report for Consolidated Electric Distributors, INC. is published. One employer, no account, unsubscribe in one click.
Site address
3535 N HOLLAND-SYLVANIA ROAD STE B
City
TOLEDO
State
OH
ZIP
43615
Mailing
3535 N HOLLAND-SYLVANIA ROAD STE B, TOLEDO, OH 43615
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
453998
Employees
21
Ownership type
A

6 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 1 exposed
Issued
Aug 23, 2016
Penalty
Initial $12,471 · Current $7,483 Reduced
OSH ACT of 1970 Section (5)(a)(1): Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to:    a.)    Consolidated Electric Distributors, Inc. dba All Phase Electric Supply Co. located at 3535 N. Holland Sylvania Rd. Toledo, OH 43615;  The employer did not ensure employees were protected from fall hazards while fixing gutters on the backside of the building. On April 15, 2016, an employee was lifted up on a pallet by the Raymond Renewed stand up forklift to fix gutter seams, and fell approximately 8-10 to the asphalt below after the forklift hit the door ramp.     Abatement method would be to ensure a manufacturer approved personnel cage is used when lifting personnel to perform this type of work. Additionally, no longer performing this type of work in house, and hiring a 3rd party professional would also be acceptable abatement.  -Follow the guidelines of ANSI B56.1-2005: Safety Standard for Low Lift and High Lift Trucks.   4.17.1 Only operator-up high lift trucks have been designed to lift personnel. If a work platform is used on trucks designed and intended for handling materials, the requirements of paras. 4.17.2 and 4.17.3 shall be met for the protection of personnel.               4.17.2 Whenever a truck is used to elevate personnel, the following precautions for the protection of personnel shall be taken:               (c)Be certain that required restraining means such as railings, chains cable, body belt(s) with lanyard(s), or deceleration devices, etc. are in place and properly used.
Recent events (2)
  • — I (S) $7483
  • — Z (S) $12471

1910.178 L03

Serious Gravity 10 1 instance 21 exposed
Issued
Aug 23, 2016
Abate by
Sep 23, 2016
Penalty
Initial $12,471 · Current $7,482 Reduced
29 CFR 1910.178(l)(3): Training program content. Powered industrial truck operators did not receive initial training in accordance with paragraph (l) of this section:     a.)    Consolidated Electric Distributors, Inc. dba All Phase Electric Supply Co. located at 3535 N. Holland Sylvania Rd. Toledo, OH; On or about April 22, 2016, the employer did not ensure employees were trained in the safe operation of forklifts, including but not limited to the use of ramps and other sloped surfaces that could affect the vehicles stability.
Recent events (2)
  • — I (S) $7482
  • — Z (S) $12471

1910.178 L06

Serious Gravity 5 1 instance 21 exposed
Issued
Aug 23, 2016
Abate by
Sep 23, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l):     a.)    Consolidated Electric Distributors, Inc. dba All Phase Electric Supply Co. located at 3535 N. Holland Sylvania Rd. Toledo, OH; On or about April 22, 2016, the employer did not ensure employees were certified to operate the stand up and sit down forklifts. Employees are required to move product throughout the warehouse and are exposed to struck by hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1904.29 A

Other-than-serious 1 instance 21 exposed
Issued
Aug 23, 2016
Abate by
Sep 23, 2016
Penalty
Initial $1,000 · Current $600 Reduced
29 CFR 1904.29(a): The employer did not use an OSHA 300, 301 and 300A Form or equivalent.     a.)    Consolidated Electric Distributors, Inc. dba All Phase Electric Supply Co. located at 3535 N. Holland Sylvania Rd. Toledo, OH 43615; On or about April 22, 2016, the employer did not ensure OSHA 300 Injury and Illness logs were kept to track recordable injuries.
Recent events (2)
  • — I (O) $600
  • — Z (O) $1000

1904.39 A02

Other-than-serious 1 instance 21 exposed
Issued
Aug 23, 2016
Penalty
Initial $5,000 · Current $3,000 Reduced
29 CFR 1904.39(a)(2): The employer did not report an in-patient hospitalization, amputation, or loss of an eye as a result of a work-related incident to OSHA within twenty-four (24) hours.     a.)    Consolidated Electric Distributors, Inc. dba All Phase Electric Supply Co. located at 3535 N. Holland Sylvania Rd. Toledo, OH 43615; On or about April 22, 2016, the employer did not ensure the hospitalization that occurred on April 15, 2016, was reported to the Toledo Area Office within 24 hours of the incident.
Recent events (2)
  • — I (O) $3000
  • — Z (O) $5000

1910.178 Q07

Other-than-serious 1 instance 21 exposed
Issued
Aug 23, 2016
Abate by
Sep 23, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.178(q)(7): Industrial trucks were not being examined before being placed in service:     a.)    Consolidated Electric Distributors, Inc. dba All Phase Electric Supply Co. located at 3535 N. Holland-Sylvania Rd. Toledo, OH; On or about April 22, 2016, the employer did not ensure powered industrial vehicles were inspected before each use. Employees are required to operate a liquid propane, sit down forklift and a standup Raymond battery powered to move material around and are exposed to struck by hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341418994.