SAINT ALBANS, WV ·
OSHA Inspection: SAINT ALBANS WINDOW MANUFACTURING, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of SAINT ALBANS WINDOW MANUFACTURING, INC. in 2141 MACCORKLE AVENUE, SAINT ALBANS, WV 25177 (NAICS 326199). OSHA activity number 341423077.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SAINT ALBANS WINDOW MANUFACTURING, INC.
- Site address
- 2141 MACCORKLE AVENUE
- City
- SAINT ALBANS
- State
- WV
- ZIP
- 25177
- Mailing
- 2141 MACCORKLE AVENUE, SAINT ALBANS, WV 25177
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 30
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1910.212 A01
- Issued
- Jun 28, 2016
- Abate by
- Jul 11, 2016
- Penalty
- Initial $3,500 · Current $0 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) Shop: On or about April 22, 2016 a Sampson DC-10 notch saw did not have a method of machine guarding in place to prevent access to the bottom of the machine where employees can make contact with the two blades while cleaning out the saw's scrap tub.
Recent events (3)
- · F (S) $0
- · C (S) $3500
- · Z (S) $3500
1910.147 D03
- Issued
- Jun 28, 2016
- Abate by
- Jul 11, 2016
- Penalty
- Initial $0 · Current $1,000
General-duty citation text
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): (a) Shop: On or about April 22, 2016 an employee who operates the Sampson DC-10 Notch Saw did not de-energize the saw by disconnecting the electrical power and the air line prior to reaching his hand into the saw past the front guard to remove vinyl jam debris that had not fallen into the waste bin.
Recent events (3)