Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PENNMARK TECHNOLOGIES CORPORATION

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of PENNMARK TECHNOLOGIES CORPORATION in 1170 LOWER DEMUNDS RD, DALLAS, PA 18612 (NAICS 332322). OSHA activity number 341425759.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Pennmark Technologies Corporation — free Get an email when a new federal OSHA severe-injury report for Pennmark Technologies Corporation is published. One employer, no account, unsubscribe in one click.
Site address
1170 LOWER DEMUNDS RD
City
DALLAS
State
PA
ZIP
18612
Mailing
1170 LOWER DEMUNDS RD, DALLAS, PA 18612
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332322
Employees
140
Ownership type
A

2 citations on file for this inspection.

1910.305 G02 III

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Jun 30, 2016
Abate by
Jul 13, 2016
Penalty
Initial $6,300 · Current $0 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief is provided that will prevent pulls from being directly transmitted to joints or terminal screws:  a) Production Area: The electrical cable connecting a foot switch to the Niagara mechanical press brake was not equipped with a device that provided adequate strain relief to prevent pulls from being transmitted to the terminal connections, on or about April 26, 2016.  ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $6300

1910.212 A03 II

Repeat Gravity 10 1 instance 2 exposed
Issued
Jun 30, 2016
Abate by
Aug 17, 2016
Penalty
Initial $13,860 · Current $10,000 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):    a) Production Area: The point of operation on the Niagara 90 ton mechanical press brake, model #1B60-8-10,  was not guarded in such a manner as to prevent the operator from having any part of his body in the die area during the operating cycle. An employee suffered an amputation injury while operating the press when his fingers were caught in the die area during the operating cycle, on or about April 22, 2016.    ABATEMENT CERTIFICATION AND DOCUMENTATION REQUIRED    Pennmark Technologies Corporation was previously cited for a violation of this Occupational Safety and Health Administration standard or its equivalent standard, 29 CFR 1910.212(a)(3)(ii), which was contained in OSHA inspection number 1048919, citation number 1, item number 2 and was affirmed as a final order on 9/15/2015, with respect to a workplace located at Lower Demunds Road, Dallas, PA.
Recent events (2)
  • — I (R) $10000
  • — Z (R) $13860

View Pennmark Technologies Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341425759.