Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,871Inspections Most recent open 2026-07-30 Last loaded 2026-08-03

OSHA Inspection: BOB POUND DRILLING, INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BOB POUND DRILLING, INC in BERTIE 1-33 WELL, SEC 33-6N-9E, HUGHES CTY, ATWOOD, OK 74827 (NAICS 213111). OSHA activity number 341426070.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch BOB Pound Drilling, INC for free Get an email when a new federal OSHA severe-injury report for BOB Pound Drilling, INC is published. One employer, no account, unsubscribe in one click.
Site address
BERTIE 1-33 WELL, SEC 33-6N-9E, HUGHES CTY
City
ATWOOD
State
OK
ZIP
74827
Mailing
121 W 6TH ST, BRISTOW, OK 74010
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213111
Employees
13
Ownership type
A

25 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 4 instances 13 exposed
Issued
Aug 30, 2016
Abate by
Sep 8, 2016
Penalty
Initial $3,564 · Current $1,200 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees:    Drilling rig:  On or about April 21, 2016, and times prior to, employees operated a drilling rig during the drilling of an oil/gas well without the derrick being adequately supported.  This exposed the employees to the hazard of being struck by the falling derrick or falling from the derrick to the ground or drilling floor.  The inadequacies included but were not limited to:    a)  All guyline connection loops were formed by only one wire rope clip.    b)  Some of the wire rope clips were installed backwards.    c)  The southeast racking board guyline had numerous broken wires in the loop and along its lower end.    d)  Both north derrick lines were anchored to the mud pump skid.
Recent events (2)
  • · I (S) $1200
  • · Z (S) $3564

5(a)(1)

Serious Gravity 5 1 instance 9 exposed
Issued
Aug 30, 2016
Abate by
Sep 8, 2016
Penalty
Initial $2,850 · Current $1,200 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees:    Well site:  On or about April 21, 2016, employees operating a drilling rig during the drilling of an oil/gas well worked with and around the unsecured high pressure drilling mud lines.  This exposed the employees to the hazard of being struck by the lines and drilling mud in the event of a line failure.
Recent events (2)
  • · I (S) $1200
  • · Z (S) $2850

1910.27 D01 II

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 30, 2016
Abate by
Sep 8, 2016
Penalty
Initial $3,564 · Current $1,200 Reduced
29 CFR 1910.27(d)(1)(ii): Cages or wells were not provided for fixed ladders of more than 20 feet (except as provided in subparagraph 5 of this paragraph) to a maximum unbroken length of 30 feet:    Rig:  On or about April 21, 2016, and times prior to, employees maintaining the rig derrick and working from the derrick board accessed the derrick from an uncaged ladder attached to the derrick.  Beside the ladder not being caged no alternative fall protection form was provided.  This exposed the employees to the hazard of falling from over 20 feet.
Recent events (2)
  • · I (S) $1200
  • · Z (S) $3564

1910.132 D01

Serious Gravity 5 1 instance 13 exposed
Issued
Aug 30, 2016
Abate by
Sep 22, 2016
Penalty
Initial $3,564 · Current $1,200 Reduced
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE):    Well site:  On or about April 22, 2016, and times prior to, employees operating a drilling rig during the drilling of an oil/gas well were exposed to physical and chemical hazards whose effects may be mitigated by the use of personal protective equipment.  The employer had not conducted an assessment of the site activities to determine what equipment was needed.  The employees were exposed to hazards as falling objects, flying objects/debris, contact with corrosive materials, and the manually handling of sharp edges among others.
Recent events (2)
  • · I (S) $1200
  • · Z (S) $3564

1910.146 C01

Serious Gravity 1 1 instance 13 exposed
Issued
Aug 30, 2016
Abate by
Oct 14, 2016
Penalty
Initial $2,138 · Current $1,200 Reduced
29 CFR 1910.146(c)(1): The employer did not evaluate the workplace to determine if any spaces were permit-required confined spaces:    Well site:  On or about April 22, 2016, and times prior to, employees operating a drilling rig during the drilling on an oil/gas well worked with and tended the rig permit confined spaces, the diesel and water tanks.  The employer had not conducted a survey of the permit confined spaces on the well site.  This exposed the employees to the hazards of engulfment, fire, and/or air contaminates.
Recent events (2)
  • · I (S) $1200
  • · Z (S) $2138

1910.151 B

Serious Gravity 1 1 instance 12 exposed
Issued
Aug 30, 2016
Abate by
Sep 22, 2016
Penalty
Initial $2,138 · Current $1,200 Reduced
29 CFR 1910.151(b): In the absence of an infirmary, clinic, or hospital in near proximity to the workplace which is used for the treatment of all injured employees, a person or persons adequately trained to render first aid were not available and adequate first aid supplies were not readily available:    Well site:  On or about April 21, 2016, and times prior to, employees engaged in the operation of a drilling rig during the drilling of an oil/gas well.  There was no person or close medical services available to render first aid or provide emergency medical treatment; and the provided first aid supplies were deficient.  This exposed the employees to the hazard of delayed medical services for injuries as but not limited to blunt force trauma, lacerations, and both thermal and chemical burns .
Recent events (2)
  • · I (S) $1200
  • · Z (S) $2138

1910.151 C

Serious Gravity 1 1 instance 6 exposed
Issued
Aug 30, 2016
Abate by
Oct 14, 2016
Penalty
Initial $2,138 · Current $1,200 Reduced
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:    Mud pump area:  On or about April 21, 2016, employees operating the drilling rig mud system used corrosive materials such as caustic soda beads.  No facilities were provided for the employees use exposing them to the hazard of prolonged contact with a corrosive material.
Recent events (2)
  • · I (S) $1200
  • · Z (S) $2138

1910.157 C04

Serious Gravity 1 1 instance 13 exposed
Issued
Aug 30, 2016
Abate by
Sep 22, 2016
Penalty
Initial $2,138 · Current $1,200 Reduced
29 CFR 1910.157(c)(4): Portable fire extinguishers were not maintained in a fully charged and operable condition:      Southeast rig guyline anchorage :  On or about April 21, 2016, and times prior to, employees were engaged in the operation of a drilling rig during the drilling of an oil/gas well were furnished with an unserviceable fire extinguisher.  This exposed the employees to fire hazards.
Recent events (2)
  • · I (S) $1200
  • · Z (S) $2138

1910.157 E02

Serious Gravity 1 1 instance 13 exposed
Issued
Aug 30, 2016
Abate by
Sep 22, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly:  Southeast rig guyline anchorage :  On or about April 21, 2016, and times prior to, employees were engaged in the operation of a drilling rig during the drilling of an oil/gas well were furnished with an unserviceable fire extinguisher that had not received a monthly inspection.  This exposed the employees to fire hazards.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.157 E03

Serious Gravity 1 1 instance 13 exposed
Issued
Aug 30, 2016
Abate by
Sep 22, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check:  Southeast rig guyline anchorage :  On or about April 21, 2016, and times prior to, employees were engaged in the operation of a drilling rig during the drilling of an oil/gas well were furnished with an unserviceable fire extinguisher that had not received an annual inspection.  This exposed the employees to fire hazards.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.178 L01 I

Serious Gravity 5 6 instances 9 exposed
Issued
Aug 30, 2016
Abate by
Oct 14, 2016
Penalty
Initial $2,850 · Current $1,200 Reduced
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):    Well site:  On or about April 22, 2016, and times prior to, employees who operated a forklift to support oil/gas well drilling activities had not received the required training.  This exposed the employees on site to the hazard of being struck by the forklift and/or it load, and the forklift operators to the hazard of overturning the forklift.
Recent events (2)
  • · I (S) $1200
  • · Z (S) $2850

1910.212 A01

Serious Gravity 5 2 instances 6 exposed
Issued
Aug 30, 2016
Abate by
Sep 15, 2016
Penalty
Initial $2,850 · Current $1,200 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    Mud pump skid:  On or about April 21, 2016, and times prior to, employees operating the a rig's drilling mud system during the drilling of an oil/gas well worked around unguarded machinery.  This exposed the employees to the hazard of being struck by in the following instances:    a)  The mud pump pressure relief valve utilizing a shear pin did not have a cap.    b)  The reciprocating pump rods were missing the access guards.
Recent events (2)
  • · I (S) $1200
  • · Z (S) $2850

1910.219 D01

Serious Gravity 1 2 instances 6 exposed
Issued
Aug 30, 2016
Abate by
Sep 15, 2016
Penalty
Initial $2,138 · Current $1,200 Reduced
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):    Mud pump skid:  On or about April 21, 2016, and times prior to, employees were operating and maintaining the rig mud pump during the drilling of an oil/gas well.  The mud pump had unguarded pulleys and a belt exposing the employees to the hazard of in running nip points.
Recent events (2)
  • · I (S) $1200
  • · Z (S) $2138

1910.219 E03 I

Serious Gravity 1 1 instance 6 exposed
Issued
Aug 30, 2016
Abate by
Sep 15, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o):   Mud pump skid:  On or about April 21, 2016, and times prior to, employees were operating and maintaining the rig mud pump during the drilling of an oil/gas well.  The mud pump had unguarded pulleys and a belt exposing the employees to the hazard of in running nip points.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.304 G01 IV

Serious Gravity 1 1 instance 13 exposed
Issued
Aug 30, 2016
Abate by
Sep 8, 2016
Penalty
Initial $2,138 · Current $1,200 Reduced
29 CFR 1910.304(g)(1)(iv)(A): AC systems of 50 volts to 1000 volts were not grounded under the following condition:  the system was so grounded that the maximum voltage to ground on the ungrounded conductor does not exceed 150 Volts, unless exempted by paragraph (g)(1)(v) of this section:    Drilling rig:  On or about April 21, 2016, employees operated a drilling rig during the drilling of an oil/gas well used a trailer mounted generator to electricity to the rig.  The generator was not grounded.  This exposed the employees to the hazard of electrical shock.
Recent events (2)
  • · I (S) $1200
  • · Z (S) $2138

1910.304 G06 IV B

Serious Gravity 1 3 instances 13 exposed
Issued
Aug 30, 2016
Abate by
Sep 8, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.304(g)(6)(iv)(B): Exposed noncurrent-carrying metal parts of fixed equipment that may become energized were not ground when located in a wet or damp location and were not isolated:  Drilling rig:  On or about April 21, 2016, and times prior to, employees operating a drilling rig during the drilling of an oil/gas well used electrical lights and other electrical equipment mounted on rig equipment.  The equipment was not grounded exposing the employees to the hazard of electrical shock.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.305 G01 IV A

Serious Gravity 1 1 instance 13 exposed
Issued
Aug 30, 2016
Abate by
Sep 8, 2016
Penalty
Initial $2,138 · Current $1,200 Reduced
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:    Drilling rig dog house: On or about April 21, 2016, and times prior to, employees operated a drilling rig during the drilling of an oil/gas well.  The employees were exposed to the hazard of electrical shock from improper use of a flexible cord supplying a fixed light fixture.
Recent events (2)
  • · I (S) $1200
  • · Z (S) $2138

1910.305 G02 II

Serious Gravity 1 2 instances 13 exposed
Issued
Aug 30, 2016
Abate by
Sep 8, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(ii): Flexible cords were not used only in continuous lengths without splice or tap:  Drilling rig:  On or about April 21, 2016, and times prior to, employees operating a drilling rig during the drilling of an oil/gas well worked around and with electric cords that were improperly spliced.  This exposed the employees to the hazard of electrical shock in the following instances:  a)  Dog house:  the cord supplying an overhead light where a hard usage cord was spliced to fixture wire.  b)  Mud pump skid:  the cord supplying a pole mounted light where a hard usage cord was spliced to two individual wires and another cord section.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.305 J02 VI

Serious Gravity 1 3 instances 13 exposed
Issued
Aug 30, 2016
Abate by
Sep 8, 2016
Penalty
Initial $2,138 · Current $1,200 Reduced
29 CFR 1910.305(j)(2)(vi): A receptacle installed in a wet location where the product intended to be plugged into it was not to be attended while in use (for example, sprinkler system controllers, landscape lighting, and holiday lights) did not have an enclosure that was weatherproof with the attachment plug cap inserted or removed:    Drilling rig:  On or about April 21, 2016, employees operating a drilling rig during the drilling of an oil/gas well used electrical receptacles.  Some receptacles were open to the elements exposed the employees to the hazard of electrical shock in the following instances:    a)  On the mud pump skid a metal box with dual receptacles.    b)  On the mud pump skid a yellow 5 way receptacle adapter.    c)  At the derrick base a yellow 5 way receptacle adapter
Recent events (2)
  • · I (S) $1200
  • · Z (S) $2138

1910.1200 E01

Serious Gravity 1 1 instance 13 exposed
Issued
Aug 30, 2016
Abate by
Oct 14, 2016
Penalty
Initial $2,138 · Current $1,200 Reduced
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met and which includes the requirements of 29 CFR 1910(e)(1)(I) and (e)(1)(ii):    Well site:  On or about April 22, 2016, and times prior to, employees operating a drilling rig during the drilling of an oil/gas well used materials as caustic soda beads, lignite, bentonite, petroleum based lubricants, and diesel .  The employer did not have a program.  This exposed to the employees to the hazards of the materials as but not limited to:  fire and explosion, silica dust, and corrosive contact with the body.
Recent events (2)
  • · I (S) $1200
  • · Z (S) $2138

1910.1200 F06

Serious Gravity 1 1 instance 13 exposed
Issued
Aug 30, 2016
Abate by
Oct 14, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(f)(6): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the information specified under paragraphs (f)(6)(i) through (ii) of this section:  Drilling rig:  On or about April 22, 2016, and times prior to, employees operating a drilling rig during the drilling of an oil/gas well used the rig diesel tank to fuel the rig engines.  The tank was not marked either as to its contents or hazards.  The employees were exposed to the hazard of the diesel fuel as but not limited to defatting of the skin, fire, and air contaminant above the permissible exposure limits.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1904.32 B06

Other-than-serious 1 instance 16 exposed
Issued
Aug 30, 2016
Abate by
Oct 14, 2016
Penalty
Initial $0 · Current $0
29 CFR 1904.32(b)(6): The Summary of Work-Related Injuries and Illnesses (OSHA Form 300A or equivalent) for the previous year was not posted between February 1st and April 30th:   The Summary for 2015 was not available.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.23 C01

Other-than-serious 2 instances 6 exposed
Issued
Aug 30, 2016
Abate by
Sep 22, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent):  Drilling rig:  On or about April 21, 2016, employees operating a drilling rig during the drilling of an oil/gas well worked on the rig pipe handling/storage trailers.  The trailer surfaces were not provided with guard rails and were over 4 feet.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.23 D01 III

Other-than-serious 2 instances 13 exposed
Issued
Aug 30, 2016
Abate by
Sep 22, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.23(d)(1)(iii): Stairway(s) less than 44 inches wide having both sides open, did not have one stair railing on each side:  Pipe trailers:  On or about April 21, 2016, and times prior to, employees working on the pipe trailers during the drilling of an oil/gas well used 2 stairs to access the trailers from the ground.  The stairs did not have handrails installed.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.334 C02

Other-than-serious 1 instance 6 exposed
Issued
Aug 30, 2016
Abate by
Sep 8, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.334(c)(2): When there was a defect or evidence of damage that could expose an employee to injury, the defective or damaged item was not removed from service but was used before repairs and tests necessary to render the equipment safe had been made:  Drilling rig:  On or about April 21, 2016, and times prior to, employees rigging up a drilling rig for the drilling of an oil/gas rig connected the generator to cord sets supplying the rig.  At the generator one cord set outer insulation was separated from the attachment plug.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341426070.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.