SYRACUSE, NY —
OSHA Inspection: BURKE CONTRACTING, LLC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of BURKE CONTRACTING, LLC. in 1700 WEST GENESEE STREET, SYRACUSE, NY 13204 (NAICS 236220). OSHA activity number 341426351.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BURKE CONTRACTING, LLC.
- Site address
- 1700 WEST GENESEE STREET
- City
- SYRACUSE
- State
- NY
- ZIP
- 13204
- Mailing
- 6838 EAST GENESEE STREET, FAYETTEVILLE, NY 13066
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 5
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.28 A
- Issued
- May 16, 2016
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1926.28(a): Appropriate personal protective equipment was not worn by employee(s) in all operations where there was exposure to hazardous conditions: a) Second floor, north end, on or about 4-26-16: One employee was cutting metal studs using a chop saw with a fiber reinforced abrasive cutting blade, without using eye protection.
Recent events (2)
- — I (S) $1200
- — Z (S) $2000
1926.403 B02
- Issued
- May 16, 2016
- Abate by
- May 24, 2016
- Penalty
- Initial $1,600 · Current $960 Reduced
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: a) First floor, northeast corner, on or about 4-26-16: Employees were using various power tools plugged into a 4"x4" metal box/quad receptacle assembly that was not being used as designed or as "listed and labeled". b) Second floor, northeast corner, on or about 4-26-16: Employees were using various power tools plugged into a 4"x4" metal box/duplex receptacle assembly that was not being used as designed or as "listed and labeled". ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM
Recent events (2)
- — I (S) $960
- — Z (S) $1600
1926.404 B01 II
- Issued
- May 16, 2016
- Abate by
- May 24, 2016
- Penalty
- Initial $1,600 · Current $0 Reduced
General-duty citation text
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupters for personal protection: a) Second floor, northeast corner, on or about 4-26-16: Employees were using various power tools plugged into extension cords and a 4"x4" metal box/duplex receptacle assembly that was not protected by a ground fault circuit interrupter (GFCI). ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM
Recent events (2)
- — I (S) $0
- — Z (S) $1600
More inspections at Burke Contracting, LLC.
View Burke Contracting, LLC.'s full OSHA safety record →
More inspections in this industry (NAICS 236220)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341426351.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.