MELROSE PARK, IL —
OSHA Inspection: GENERAL MANUFACTURING, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of GENERAL MANUFACTURING, LLC in 1725 N. 33RD AVENUE, MELROSE PARK, IL 60160 (NAICS 335312). OSHA activity number 341432516.
Where did this inspection happen?
- Establishment
- GENERAL MANUFACTURING, LLC
- Site address
- 1725 N. 33RD AVENUE
- City
- MELROSE PARK
- State
- IL
- ZIP
- 60160
- Mailing
- 3131 W. SOFFEL AVENUE, MELROSE PARK, IL 60160
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 335312
- Employees
- 50
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $2520.00 · Current $1310.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding were not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Lathe Department- On May 4, 2016, the employer did not ensure that employees were adequately protected from rotating parts and flying chips from equipment, such as the Mori Seiki ENGL Lathe. The guard on the equipment was not being used while the equipment was in operation.
Recent events (2)
- — I (S) $1310
- — Z (S) $2520
1910.179 J02 III
- Issued
- Penalty
- Initial $1964.00 · Current $1020.00 Reduced
General-duty citation text
29 CFR 1910.179(j)(2)(iii): Inspections of hooks, with a certification record which includes the date of inspection, the signature of the person who performed the inspection and the serial number, or other identifier of the hook inspected, were not performed to ensure that the equipment is operating in a safe and reliable condition: a) VTL Department- On April 27, 2016, the employer did not ensure that damage or deformation of the hook safety latches on crane equipment for M69 and M73 were identified during the daily and monthly inspections and evaluated to ensure that the equipment is operating in a safe and reliable condition.
Recent events (2)
- — I (S) $1020
- — Z (S) $1964
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $9800.00 · Current $5170.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) CNC Milling, Lathe, and Grinding Departments- On April 27, 2016, the employer did not ensure that guards or methods of guarding were adequate to protect employees from point of operation hazards, rotating parts, and flying chips from equipment, such as M7 Mori Seiki CNC, M18 CNC, R83 150 CNC, R25 Mitsubishi CNC Grinder. The safety interlocks on equipment were damaged, missing or not activated while the equipment was in use. General Manufacturing, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.212(a)(1), which was contained in OSHA inspection number 1062853, Citation number 1, Item number 3 and was affirmed as a final order on June 10, 2015, with respect to the workplace located at 1725 N. 33rd Avenue in Melrose Park, Illinois 60160.
Recent events (2)
- — I (R) $5170
- — Z (R) $9800
1910.179 G01 V
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.179(g)(1)(v): Pendant control boxes shall be constructed to prevent electrical shock and shall be clearly marked for identification of functions: a) VTL Department- On April 27, 2016, the employer did not ensure that the pendant control box on equipment, such as the crane for M73, was clearly marked to identify the functions of the control buttons.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at GENERAL MANUFACTURING, LLC
MELROSE PARK, IL—2016-04-27 00:00:00
GENERAL MANUFACTURING, LLC
MELROSE PARK, IL—2015-05-13 00:00:00
GENERAL MANUFACTURING, LLC
View GENERAL MANUFACTURING, LLC's full OSHA safety record →
More inspections in this industry (NAICS 335312)
COLUMBUS, IN—2026-06-18 00:00:00
CUMMINS CMEP
LONGMONT, CO—2026-06-15 00:00:00
STORED ENERGY SYSTEMS
THOMASTON, CT—2026-04-02 00:00:00
FAIRBANKS MORSE DEFENSE
SAN JUAN, PR—2026-03-17 00:00:00
RK POWER GENERATOR CORP
MUSKEGO, WI—2026-03-12 00:00:00
MTI MOTION, LLC
More inspections in IL
FRANKFORT, IL—2026-07-17 00:00:00
QUANTUM TECHNICAL SERVICES INC.
ROCK ISLAND, IL—2026-07-17 00:00:00
AUGUSTANA COLLEGE