Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,547Inspections Most recent open 2026-09-01 Last loaded 2026-09-04

OSHA Inspection: VISION DESIGN, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of VISION DESIGN, LLC in 1120 FEDERAL ROAD, BROOKFIELD, CT 06804 (NAICS 323113). OSHA activity number 341437580.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Vision Design, LLC for free Get an email when a new federal OSHA severe-injury report for Vision Design, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
VISION DESIGN, LLC
Site address
1120 FEDERAL ROAD
City
BROOKFIELD
State
CT
ZIP
06804
Mailing
1120 FEDERAL ROAD, BROOKFIELD, CT 06804
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
323113
Employees
16
Ownership type
Private (A)

12 citations on file for this inspection.

1910.22 A01

Serious Gravity 5 3 instances 5 exposed
Issued
May 11, 2016
Penalty
Initial $1,600 · Current $960 Reduced
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms, and service rooms shall be kept clean and orderly and in a sanitary condition.    WORKSHOP:  The following metal conduits and flexible cords were creating a tripping hazard:       1.  The flexible cords and metal conduit for the Infrared Curing Power System.      ABATED DURING THE INSPECTION      2.  The flexible cords for the InLine Number Press.        ABATED DURING THE INSPECTION    3.  The metal conduit for the M&R Sprint 2000 Drying Over.      ABATED DURING THE INSPECTION
Recent events (2)
  • · I (S) $960
  • · Z (S) $1600

1910.132 D01

Serious Gravity 5 1 instance 4 exposed
Issued
May 11, 2016
Abate by
Jun 28, 2016
Penalty
Initial $1,600 · Current $960 Reduced
29 CFR 1910.132(d)(1): The employer shall assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE).     WORKSHOP:  The Workplace Hazard Assessment to determine necessitate and appropriate types of personal protective equipment (PPE) for the employees was not performed.
Recent events (2)
  • · I (S) $960
  • · Z (S) $1600

1910.132 F01

Serious Gravity 5 1 instance 4 exposed
Issued
May 11, 2016
Abate by
Jun 28, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.132(f)(1): The employer shall provide training to each employee who is required by this section to use personal protective equipment (PPE).  WORKSHOP:   Employees were not provided with information and training on the Workplace Hazard Assessment for personal protective equipment (PPE).
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.178 L04 II E

Serious Gravity 5 1 instance 1 exposed
Issued
May 11, 2016
Penalty
Initial $1,600 · Current $960 Reduced
29 CFR 1910.178(l)(4)(ii)(E):  Refresher training, including an evaluation of the effectiveness of that training shall be conducted when a condition in the workplace changes in a manner that could affect safe operation of the truck:    WORKSHOP:  The powered industrial truck (PIT) operator, who had operated a PIT from a previous employer was not provided with a refresher training and an evaluation.        ABATED DURING THE INSPECTION
Recent events (2)
  • · I (S) $960
  • · Z (S) $1600

1910.304 F01 IV

Serious Gravity 5 1 instance 4 exposed
Issued
May 11, 2016
Penalty
Initial $2,000 · Current $1,740 Reduced
29 CFR 1910.304(f)(1)(iv): Overcurrent devices shall be readily accessible to each employee or authorized building management personnel. These overcurrent devices may not be located where they will be exposed to physical damage or in the vicinity of easily ignitable material.      WORKSHOP:  The following electrical panels having built-in overcurrent protection devices were blocked with aluminum, racks, and cardboards:      1.  Electrical panel #3; Fed from panel #2.   2.  Electrical panel facing South.      ABATED DURING THE INSPECTION
Recent events (2)
  • · I (S) $1740
  • · Z (S) $2000

1910.305 G01 IV E

Serious Gravity 5 1 instance 1 exposed
Issued
May 11, 2016
Penalty
Initial $1,600 · Current $960 Reduced
29 CFR 1910.305(g)(1)(iv)(E): Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used where concealed behind building walls, ceilings, or floors:    WORKSHOP:  The flexible extension cord, used to energy the Heat Transfer Press, unknown identification traveled between the wall and the work table, went through boxes, racks, paper containing opened top ink containers.        ABATED DURING THE INSPECTION
Recent events (2)
  • · I (S) $960
  • · Z (S) $1600

1910.305 G02 II

Serious Gravity 5 1 instance 1 exposed
Issued
May 11, 2016
Penalty
Initial $1,600 · Current $960 Reduced
29 CFR 1910.305(g)(2)(ii): Flexible cords may be used only in continuous lengths without splice or tap. Hard-service cord and junior hard-service cord No. 14 and larger may be repaired if spliced so that the splice retains the insulation, outer sheath properties, and usage characteristics of the cord being spliced.    WORKSHOP:  The red flexible extension cord, connected to the the yellow flexible cord of the DeWalt chop saw was spliced and repaired with electric tape.      ABATED DURING THE INSPECTION
Recent events (2)
  • · I (S) $960
  • · Z (S) $1600

1910.1200 E01

Serious Gravity 5 1 instance 4 exposed
Issued
May 11, 2016
Abate by
Jun 28, 2016
Penalty
Initial $1,600 · Current $960 Reduced
29 CFR 1910.1200(e)(1): Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met.    WORKSHOP:  A written hazard communication program including the Globalized Harmonized System was not established and implemented where employees were required to work with chemicals, such as (but not limited to) screen wash and purple 2 emulsion.
Recent events (2)
  • · I (S) $960
  • · Z (S) $1600

1910.1200 G01

Serious Gravity 5 1 instance 3 exposed
Issued
May 11, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(g)(1): Employers shall have a safety data sheet in the workplace for each hazardous chemical which they use.  WORKSHOP:  The material safety data sheet (MSDS) for the press wash 2110 was not maintained.    ABATED DURING THE INSPECTION
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.1200 H01

Serious Gravity 5 1 instance 4 exposed
Issued
May 11, 2016
Abate by
Jun 28, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1): Employers shall provide employees with effective information and training on hazardous chemicals in their work area at the time of their initial assignment, and whenever a new physical or health hazard the employees have not previously been trained about is introduced into their work area. Information and training may be designed to cover categories of hazards (e.g., flammability, carcinogenicity) or specific chemicals. Chemical-specific information must always be available through labels and safety data sheets.  WORKSHOP:  The employees, required to work with chemicals, such as (but not limited to) screen wash and purple 2 emulsion were not provided with training and information in the hazard communication program, Globalized Harmonized System.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.101 B

Other-than-serious 1 instance 1 exposed
Issued
May 11, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.101(b): "Compressed gases." The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks shall be in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in Sec. 1910.6.  WORKSHOP:  The argon gas cylinder was not appropriately secured.    ABATED DURING THE INSPECTION
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.157 E01

Other-than-serious 3 instances 4 exposed
Issued
May 11, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(1): The employer shall be responsible for the inspection, maintenance and testing of all portable fire extinguishers in the workplace.  WORKSHOP:  The following fire extinguishers were not inspected:  1.      Fire extinguisher labeled A, B, C.  2.     Two unmounted A, B, C fire extinguishers.  ABATED DURING THE  INSPECTION
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 341437580.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.