OSHA Inspection: VELECELA CONTRACTORS, LLC

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of VELECELA CONTRACTORS, LLC in 118-120 WINDSOR STREET, KEARNY, NJ 07032 (NAICS 238170). OSHA activity number 341442267.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Velecela Contractors, LLC for free Get an email when a new federal OSHA severe-injury report for Velecela Contractors, LLC is published. One employer, no account, unsubscribe in one click.
Site address
118-120 WINDSOR STREET
City
KEARNY
State
NJ
ZIP
07032
Mailing
316 FARLEY AVE., SCOTCH PLAINS, NJ 07076
Inspection type
Unprogrammed Other (J)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
3
Ownership type
Private (A)

2 citations on file for this inspection.

1926.451 F06

Serious Gravity 10 1 instance 3 exposed
Issued
May 9, 2016
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.451(f)(6): The clearance between scaffolds and Insulated power lines shall be as follows: Scaffolds shall not be erected, used, dismantled, altered, or moved such that they or any conductive material handled on them might come closer to exposed and energized power lines.  a.) 118-120 Windsor St. Kearny NJ  Employees were working from a ladder jack scaffold approximately less then 3 feet away from an energized insulated power line that was less then 300 volts; there by exposing employees to electrical hazards.  Violation observed on or about 04/30/2016
Recent events (1)
  • · Z (S) $2800

1926.451 G01

Serious Gravity 10 1 instance 2 exposed
Issued
May 9, 2016
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level.   a.) 118-120 Windsor St., Kearny NJ  Employees were installing exterior siding approximately 40 feet above the ground below from a ladder jack scaffold without the use of any personal fall arrest system; there-by exposing employees to fall hazards.   Violation observed on or about 4/30/2016