Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ROTO-MIX, LLC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of ROTO-MIX, LLC in 2205 EAST WYATT EARP BLVD., DODGE CITY, KS 67801 (NAICS 112990). OSHA activity number 341444115.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Roto-Mix, LLC — free Get an email when a new federal OSHA severe-injury report for Roto-Mix, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
ROTO-MIX, LLC
Site address
2205 EAST WYATT EARP BLVD.
City
DODGE CITY
State
KS
ZIP
67801
Mailing
P. O. BOX 1724, DODGE CITY, KS 67801
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
112990
Employees
70
Ownership type
A

6 citations on file for this inspection.

1910.179 J02 III

Serious Gravity 5 1 instance 20 exposed
Issued
Jul 22, 2016
Abate by
Oct 15, 2016
Penalty
Initial $3,600 · Current $1,080 Reduced
29 CFR 1910.179(j)(2)(iii): Monthly inspections of hooks, with a certification record which includes the date of inspection, the signature of the person who performed the inspection and the serial number, or other identifier, of the hook inspected, were not performed:  Employees engaged in manufacturing and maintenance activities were exposed to struck by hazards throughout the facility in that monthly inspections of hooks were not performed and properly recorded.
Recent events (2)
  • — I (S) $1080
  • — Z (S) $3600

1910.179 J02 IV

Serious Gravity 5 1 instance 20 exposed
Issued
Jul 22, 2016
Abate by
Oct 15, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.179(j)(2)(iv): Monthly inspections of hoist chains, with a certification record which includes the date of inspection, the signature of the person who performed the inspection and an identifier of the chain which was inspected, were not performed:  Employees engaged in manufacturing and maintenance activities were exposed to struck by hazards throughout the facility in that monthly inspections of hoist chains were not performed and properly recorded.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G01 IV B

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 22, 2016
Abate by
Oct 15, 2016
Penalty
Initial $3,600 · Current $1,080 Reduced
29 CFR 1910.305(g)(1)(iv)(B): Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used to run through holes in walls, ceilings, or floors.  Employees engaged in manufacturing and maintenance activities were exposed to electrical hazards in that an extension cord was run through a hole in a wall and being used in the plasma office.
Recent events (2)
  • — I (S) $1080
  • — Z (S) $3600

1910.305 G02 III

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 22, 2016
Abate by
Oct 15, 2016
Penalty
Initial $3,600 · Current $1,080 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:  Employees engaged in manufacturing and maintenance activities were exposed to electrical hazards in that strain relief was pulled in the following instances:  a) an extension cord used by employees doing grinding in the plasma area.  b) the west floor jig welder.
Recent events (2)
  • — I (S) $1080
  • — Z (S) $3600

1910.334 A02 II

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 22, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposes an employee to injury and the defective or damaged item was not removed from service and an employee was using it before repairs and tests necessary to render the equipment safe were made:  Employees engaged in manufacturing and maintenance activities were exposed to electrical hazards in that an extension cord used by employees doing grinding in the plasma area had visible damage and was still in use.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1026 D02 III

Willful 1 instance 20 exposed
Issued
Jul 22, 2016
Abate by
Dec 30, 2016
Penalty
Initial $5,000 · Current $1,500 Reduced
29 CFR 1910.1026(d)(2)(iii): The employer used the scheduled monitoring option, and monitoring revealed employee exposures to chromium (VI) to be at or above the action level; however, the employer did not perform periodic monitoring at least every six months:  The employer failed to continue periodic sampling for hexavalent chromium after levels above the action level had been identified.
Recent events (2)
  • — I (W) $1500
  • — Z (W) $5000

View Roto-Mix, LLC's full OSHA safety record →