WADSWORTH, OH —
OSHA Inspection: RADICI PLASTIC USA INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of RADICI PLASTIC USA INC. in 960 SEVILLE ROAD, WADSWORTH, OH 44281 (NAICS 325211). OSHA activity number 341445146.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RADICI PLASTIC USA INC.
- Site address
- 960 SEVILLE ROAD
- City
- WADSWORTH
- State
- OH
- ZIP
- 44281
- Mailing
- 960 SEVILLE ROAD, WADSWORTH, OH 44281
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325211
- Employees
- 87
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.23 A02
- Issued
- Jul 28, 2016
- Abate by
- Mar 1, 2017
- Penalty
- Initial $3,500 · Current $1,750 Reduced
General-duty citation text
29 CFR 1910.23(a)(2): Ladderway floor opening(s) or platform(s) were not guarded by a standard railing with standard toeboard(s) on all exposed sides (except at the entrance to opening) with passage through the railing either provided with a swinging gate or so offset that a person could walk directly into the opening: On or about May 3, 2016, employees were exposed to fall hazards, in that, there were two elevated platforms, one for the post blender and one for the hydraulic system at the #6 plastic extrusion line. The elevated platforms had vertical ladder openings that did not have a swing gate and was not offset.
Recent events (3)
- — F (S) $1750
- — C (S) $3500
- — Z (S) $3500
1910.146 C04
- Issued
- Jul 28, 2016
- Abate by
- Mar 1, 2017
- Penalty
- Initial $3,500 · Current $1,750 Reduced
General-duty citation text
29 CFR 1910.146(c)(4): When the employer decided that its employees would enter permit spaces, the employer did not develop and implement a written permit space entry program that complied with 29 CFR 1910.146: On or about May 3, 2016, The employer did not have a permit required confined space program. Employees were exposed to permit space hazards such as but not limited to asphyxiation while they were cleaning the inside of the post blenders to the number 7 and number 8 plastic extrusion lines.
Recent events (3)
- — F (S) $1750
- — C (S) $3500
- — Z (S) $3500
1910.147 D
- Issued
- Jul 28, 2016
- Abate by
- Mar 1, 2017
- Penalty
- Initial $4,900 · Current $2,450 Reduced
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): On or about May 3, 2016, employees were exposed to machine hazards associated with moving parts, in-going nip points, and thermal hazards during servicing and cleaning of the screen changer at the #6 plastic extrusion line. The employer failed to implement energy control application steps as the machine was not shut down or turned off to perform the servicing work [per the 1910.147(d)(2) requirement]. As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3), LOTO device application [(d)(4), dissipation of residual energy [(d)(5)(I)], and verification of isolation [(d)(6), were not implemented to protect employees from machine servicing hazards. Prepare for shutdown [(d)(1)] - ensure authorized employee has knowledge of the type, magnitude, the hazards, and the method or means to control the energy; Shutdown the machine or equipment [(d)(2)]; Machine isolation [(d)(3)] - Physically locate and operate all energy isolation devices that are needed to control the energy to the machine or equipment in such a manner as to isolate the machine or equipment from the energy source(s); LOTO device application [(d)(4)] - Affix a lockout or tagout device to each energy isolating device; Dissipation of residual energy [(d)(5)(i)] - relieve, disconnect, restrain, and otherwise render safe all potentially hazardous stored or residual energy; Verification of isolation [(d)(6)] - Verify that isolation and deenergization of the machine or equipment has been accomplished
Recent events (3)
- — F (S) $2450
- — C (S) $4900
- — Z (S) $4900
1910.212 A01
- Issued
- Jul 28, 2016
- Abate by
- Aug 17, 2016
- Penalty
- Initial $3,500 · Current $1,750 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: On or about May 3, 2016, on the #6 plastic extrusion line the guard over the east side of the slide plate/breaker plate assembly had a proximity switch used as an interlock. The guard had a metal contact tab that was damaged and did not contact the proximity switch, the proximity switch was ineffective as a safeguard.
Recent events (3)
- — F (S) $1750
- — C (S) $3500
- — Z (S) $3500
More inspections at Radici Plastic USA INC.
View Radici Plastic USA INC.'s full OSHA safety record →
More inspections in this industry (NAICS 325211)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341445146.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.