WASHINGTON, DC ·
OSHA Inspection: CONNELL AND SCHMIDT BUILDERS, LLC.
Programmed Related inspection · Safety discipline
At a glance
On , OSHA opened a programmed Related safety inspection of CONNELL AND SCHMIDT BUILDERS, LLC. in 728 4TH STREET, NE, WASHINGTON, DC 20024 (NAICS 236118). OSHA activity number 341445161.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CONNELL AND SCHMIDT BUILDERS, LLC.
- Site address
- 728 4TH STREET, NE
- City
- WASHINGTON
- State
- DC
- ZIP
- 20024
- Mailing
- 1527 E STREET, SE, WASHINGTON, DC 20003
What kind of inspection was it?
- Inspection type
- Programmed Related (I)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236118
- Employees
- 4
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1926.451 B05 II
- Issued
- Aug 1, 2016
- Abate by
- Aug 5, 2016
- Penalty
- Initial $2,200 · Current $2,200
General-duty citation text
29 CFR 1926.451(b)(5)(ii): The end of a platform greater than 10 feet in length extended over its support more than 18 inches and the platform was not designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilivered end: a) Exterior North Side of Structure - A mason was standing on a pumpjack scaffold work platform that extended past the end support by 48 inches, exposing the mason to a fall of 18 feet, on or about 05/02/2016. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (1)
- · Z (S) $2200
1926.452 J02
- Issued
- Aug 1, 2016
- Abate by
- Aug 5, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary: a) Exterior North Side of Structure - A mason was observed standing on a pumpjack scaffold work platform 18 feet above the ground and the poles supporting the scaffold were not provided with bracing on the bottom of the poles, on or about 05/02/2016. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (1)
- · Z (S) $0
1926.451 G01
- Issued
- Aug 1, 2016
- Abate by
- Aug 5, 2016
- Penalty
- Initial $2,200 · Current $2,200
General-duty citation text
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: a) Exterior North Side of Structure - A mason was on a pumpjack scaffold work platform while laying brick and not protected from an 18 foot fall hazard, on or about 05/02/2016. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet).
Recent events (1)
- · Z (S) $2200
More inspections in this industry (NAICS 236118)
More inspections in DC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 341445161.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.