LAFAYETTE, LA ·
OSHA Inspection: LANGLINAIS BAKING CO., INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of LANGLINAIS BAKING CO., INC. in 815 S. ST. ANTOINE ST., LAFAYETTE, LA 70507 (NAICS 311812). OSHA activity number 341446078.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LANGLINAIS BAKING CO., INC.
- Site address
- 815 S. ST. ANTOINE ST.
- City
- LAFAYETTE
- State
- LA
- ZIP
- 70507
- Mailing
- 815 S. ST. ANTOINE ST., LAFAYETTE, LA 70507
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311812
- Employees
- 45
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1910.305 B01 II
- Issued
- Jul 11, 2016
- Penalty
- Initial $4,900 · Current $1,960 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: Maintenance Shop - On or about April 28, 2016, the employer did not ensure that a metal junction box was effectively closed. The junction box is used an extension for a grinder and other hand tools.
Recent events (2)
- · I (S) $1960
- · Z (S) $4900
1910.305 G01 IV A
- Issued
- Jul 11, 2016
- Abate by
- Jul 25, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: Maintenance Shop: On or about April 28, 2016, employee(s) used a flexible chord and/or cable as a substitute for fixed wiring. The chord and/or cable was attached to a handy box that was hardwired to wall outlet being used as an extension for a grinder and other hand tools.
Recent events (2)
- · I (S) $0
- · Z (S) $0
More inspections at Langlinais Baking CO., INC.
View Langlinais Baking CO., INC.'s full OSHA safety record →
More inspections in this industry (NAICS 311812)
More inspections in LA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 341446078.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.