WEST MIFFLIN, PA ·
OSHA Inspection: KEYWELL METALS LLC
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of KEYWELL METALS LLC in 890 NOBLE DRIVE, WEST MIFFLIN, PA 15122 (NAICS 423930). OSHA activity number 341446805.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- KEYWELL METALS LLC
- Site address
- 890 NOBLE DRIVE
- City
- WEST MIFFLIN
- State
- PA
- ZIP
- 15122
- Mailing
- 890 NOBLE DRIVE, WEST MIFFLIN, PA 15122
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423930
- Employees
- 16
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1910.134 F02
- Issued
- Jun 13, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(2): Employee(s) using a tight-fitting face piece respirator were not annually fit tested: a) In the Facility, on or about April 29, 2016, the employer did not provide an employee designated as a burner an annual fit test. The employee utilizes a half mask respirator during burning operations.
Recent events (1)
- · Z (O) $0
1910.145 F06
- Issued
- Jun 13, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.145(f)(6): Caution tags were not used in minor hazard situations where a non-immediate or potential hazard or unsafe practice presents a lesser threat of employee injury: a) Stainless Steel Turning Operation, on or about April 29, 2016, the employer did not post caution tags or signs for the use of hearing protection in an area where a peak noise level of 118 decibels was reached.
Recent events (1)
- · Z (O) $0
1910.147 C06 I
- Issued
- Jun 13, 2016
- Abate by
- Jul 16, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) In the Facility, on or about April 29, 2016, the employer did not conduct a periodic inspection of the energy control procedures at least annually. Employees at the facility utilize lockout for equipment including but not limited to hydraulic bailers and drying ovens.
Recent events (1)
- · Z (O) $0
More inspections at Keywell Metals LLC
View Keywell Metals LLC's full OSHA safety record →
More inspections in this industry (NAICS 423930)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 341446805.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.