BENSALEM, PA ·
OSHA Inspection: NICON LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of NICON LLC in 3632 STREET RD., BENSALEM, PA 19020 (NAICS 236220). OSHA activity number 341446821.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NICON LLC
- Site address
- 3632 STREET RD.
- City
- BENSALEM
- State
- PA
- ZIP
- 19020
- Mailing
- 300 KIMBALL DR., PARSIPPANY, NJ 07054
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 1
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1926.701 B
- Issued
- May 13, 2016
- Abate by
- May 23, 2016
- Penalty
- Initial $2,800 · Current $2,100 Reduced
General-duty citation text
29 CFR 1926.701(b): All protruding reinforcing steel, onto and/or into which employees could fall or come against, was not guarded to eliminate the hazard of impalement: a) Construction site, retail pad - On or about April 13, 2016, protruding reinforcing steel along the foundation of the structure was not guarded to eliminate the hazard of impalement, exposing workers to serious injury.
Recent events (2)
- · I (S) $2100
- · Z (S) $2800
1926.752 A01
- Issued
- May 13, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.752(a): Before authorizing the commencement of steel erection, the controlling contractor did not ensure that the steel erector was provided with written notification that the concrete in the footings, piers and walls and the mortar in the masonry piers and walls had attained either 75 percent of the intended minimum compressive design strength or sufficient strength to support the loads imposed during steel erection and/or of any repairs, replacements and modifications to the anchor bolts. a) Construction site, retail pad - On or about April 13, 2016, the controlling contractor did not ensure the steel erector was provided documentation showing the concrete in the footings, piers and walls and the mortar in the masonry piers and walls has attained, on the basis of an appropriate ASTM standard test method of field-cured samples, either 75 percent of the intended minimum compressive design strength or sufficient strength to support the loads imposed during steel erection.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections in this industry (NAICS 236220)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 341446821.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.