Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,991Inspections Most recent open 2026-08-24 Last loaded 2026-08-27

OSHA Inspection: ATLANTIC BLUERIDGE ELEVATOR COMPANY

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ATLANTIC BLUERIDGE ELEVATOR COMPANY in NORFOLK NAVAL SHIPYARD PORTSMOUTH BUILDING 171, PORTSMOUTH, VA 23701 (NAICS 238290). OSHA activity number 341450575.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Atlantic Blueridge Elevator Company for free Get an email when a new federal OSHA severe-injury report for Atlantic Blueridge Elevator Company is published. One employer, no account, unsubscribe in one click.
Site address
NORFOLK NAVAL SHIPYARD PORTSMOUTH BUILDING 171
City
PORTSMOUTH
State
VA
ZIP
23701
Mailing
2505 SOUTH MILITARY HIGHWAY, CHESAPEAKE, VA 23320
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Union (A)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238290
Employees
14
Ownership type
Private (A)

2 citations on file for this inspection.

1926.404 B01 II

Serious Gravity 1 2 instances 2 exposed
Issued
May 26, 2016
Penalty
Initial $1,020 · Current $765 Reduced
29 CFR 1926.404(b)(1)(ii): 29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupters for personal protection:   a)    Building 171, Inside Machine Shop: On or about 04 May 2016, an extension was plugged into a wall mounted receptacle to supply power a pedestal light that was not provided with a ground fault interrupter device, thus exposing employees to a possible electrical shock hazard.  b)    Building 171, Inside Machine Shop: On or about 04 May 2016, employees plugged a three way GFCI pigtail into the female end of an extension cord then plugged the male end of the extension cord into a wall mounted receptacle, as a result employees were exposed to a possible electrical shock hazard below the GFCI protective device.  No abatement certification or documentation required.
Recent events (2)
  • · I (S) $765
  • · Z (S) $1020

1926.404 F07 IV C 5

Serious Gravity 5 1 instance 2 exposed
Issued
May 26, 2016
Penalty
Initial $1,360 · Current $1,020 Reduced
29 CFR 1926.404(f)(7)(iv)(C)(5): Exposed noncurrent-carrying metal parts of cord- and plug-connected portable hand lamps which may become energized were not grounded:(  a)    Building 171 Inside Machine Shop : On or about 04 May, 2016, employees used a portable hand lamp equipped with two conductor wires and an aluminum lamp guard that was not grounded, as a result employees were exposed to a possible electrical shock hazard.  No abatement certification or documentation required.
Recent events (2)
  • · I (S) $1020
  • · Z (S) $1360

View Atlantic Blueridge Elevator Company's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 341450575.