PECOS, TX ·
OSHA Inspection: HALLIBURTON
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of HALLIBURTON in RIG #381, 22.1 MILES NORTHWEST OF PECOS, TX, PECOS, TX 79772 (NAICS 213112). OSHA activity number 341453884.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HALLIBURTON
- Site address
- RIG #381, 22.1 MILES NORTHWEST OF PECOS, TX
- City
- PECOS
- State
- TX
- ZIP
- 79772
- Mailing
- 6155 W MURPHY, ODESSA, TX 79763
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 213112
- Employees
- 300
- Ownership type
- Private (A)
Citations
6 citations on file for this inspection.
1910.132 A
- Issued
- Oct 11, 2016
- Abate by
- Jan 9, 2017
- Penalty
- Initial $4,811 · Current $3,500 Reduced
General-duty citation text
29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered: On or about May 03, 2016 and at times prior thereto, An employee was mixing chemicals without wearing appropriate personal protective equipment (PPE). The employee was exposed to eye, face and skin injuries.
Recent events (3)
- · F (S) $3500
- · C (S) $4811
- · Z (S) $4811
1910.132 F03 III
- Issued
- Oct 11, 2016
- Abate by
- Oct 28, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(f)(3)(iii): The employer did not retrain employees when inadequacies in the affected employee's use of PPE indicated the employee had not retained the requisite understanding: On or about May 03, 2016 and at times prior thereto, an employee was mixing chemicals without using the appropriate personal protective equipment (PPE). The employee seemed to not understand the seriousness of not wearing PPE. This behavior exposed the employee to eye, face and skin injuries.
Recent events (3)
- · F (S) $0
- · C (S) $0
- · Z (S) $0
1910.304 G05
- Issued
- Oct 11, 2016
- Abate by
- Oct 28, 2016
- Penalty
- Initial $4,811 · Current $0 Reduced
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: On or about May 03, 2016 and at times prior thereto, an employee was working inside a trailer that was not grounded. The employee was exposed to electric shock and/or burn hazards.
Recent events (3)
- · F (S) $0
- · C (S) $4811
- · Z (S) $4811
1910.305 B02 I
- Issued
- Oct 11, 2016
- Abate by
- Jan 9, 2017
- Penalty
- Initial $4,811 · Current $500 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose: On or about May 03, 2016 and at times prior thereto, an employee was working in a trailer which had two outlets that had broken faceplate covers. This exposed the employee to electric shock hazards.
Recent events (3)
- · F (O) $500
- · C (S) $4811
- · Z (S) $4811
1910.305 G01 IV C
- Issued
- Oct 11, 2016
- Abate by
- Oct 28, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(C): Flexible cords and cables were used where run through doorways, windows, or similar openings: On or about May 03, 2016 and at times prior thereto, an employee was working in a trailer that had a 120V electrical cord running through a window of the trailer's door. The employee was exposed to electric shock hazards.
Recent events (3)
- · F (O) $0
- · C (O) $0
- · Z (O) $0
1910.305 J02 VII
- Issued
- Oct 11, 2016
- Abate by
- Oct 28, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(j)(2)(vii): A receptacle installed in a wet location where the product intended to be plugged into it was to be attended while in use (for example, portable tools) did not have an enclosure that was weatherproof when the attachment plug cap was removed: On or about May 03, 2016 and at times prior thereto, an employee was working in a trailer that had an exterior outlet that was missing a weatherproof enclosure. This exposed the employee to electric shock hazards.
Recent events (3)
- · F (O) $0
- · C (O) $0
- · Z (O) $0
More inspections at Halliburton
View Halliburton's full OSHA safety record →
More inspections in this industry (NAICS 213112)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 341453884.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.