Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CINEGA CUSTOM FRAMING AND DESIGN, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of CINEGA CUSTOM FRAMING AND DESIGN, INC. in 274 8TH STREET, JACKSONVILLE BEACH, FL 32250 (NAICS 238130). OSHA activity number 341454015.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Cinega Custom Framing and Design, INC. — free Get an email when a new federal OSHA severe-injury report for Cinega Custom Framing and Design, INC. is published. One employer, no account, unsubscribe in one click.
Site address
274 8TH STREET
City
JACKSONVILLE BEACH
State
FL
ZIP
32250
Mailing
553 MOONSHINE DRIVE, PONTE VEDRA BEACH, FL 32081
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
12
Ownership type
A

5 citations on file for this inspection.

1926.1408 A02

Serious Gravity 10 1 instance 3 exposed
Issued
Jul 8, 2016
Penalty
Initial $7,000 · Current $4,200 Reduced
29 CFR 1926.1408(a)(2): The employer did not determine if any part of the equipment, load line or load (including rigging and lifting accessories), if operated up to the equipment's maximum working radius in the work zone, could get closer than 20 feet to a power line:    a. On or about April 29, 2016, on the east side of the residential building, the employer failed to de-energize and ground the circuit, establish a 20-feet clearance from the 26KV power lines or follow table "A", for the T340 Terex Crane used to set trusses on a residential structure, exposing employees to electrocution hazards.
Recent events (2)
  • — I (S) $4200
  • — Z (S) $7000

1926.1408 D01

Serious Gravity 10 1 instance 1 exposed
Issued
Jul 8, 2016
Penalty
Initial $7,000 · Current $4,200 Reduced
29 CFR 1926.1408(d)(1): Part(s) of equipment, load line, or load (including rigging and lifting accessories) were allowed below an energized power line:    a. On or about April 29, 2016, on the east side of the residential building, the employer did not confirm with the utility owner/operator that the 26KV power line was de-energized and grounded prior to operating the crane below the power to lift trusses to a residential structure, the load line of the crane made contact with the power line exposing employees to electrocution hazards.
Recent events (2)
  • — I (S) $4200
  • — Z (S) $7000

1926.1413 A04 III A

Serious Gravity 10 1 instance 3 exposed
Issued
Jul 8, 2016
Penalty
Initial $7,000 · Current $4,200 Reduced
29 CFR 1926.1413(a)(4)(iii)(A): The employer did not remove from service and continued to use the crane without replacing the wire rope after contact with an energized power line:    a. On or about April 29, 2016, on the east side of the residential building, employees rigging, hooking wood roofing trusses and operating a crane were exposed to struck-by hazard because after the wire rope contacted the power lines the employer continue operating the crane and did not removed it from service.
Recent events (2)
  • — I (S) $4200
  • — Z (S) $7000

1926.1408 G01 I

Other-than-serious 1 instance 1 exposed
Issued
Jul 8, 2016
Penalty
Initial $1,100 · Current $660 Reduced
29 CFR 1926.1408(g)(1)(i): At this job site, the employer had not trained the operator of the T340 Terex Crane, serial #12324, in the procedures to be followed in the event of electrical contact with a power line. Such training must include: 1926.1408 A-F.    a.  On or about April 29, 2016, the employer did not train the operator on the procedures to follow in the event of the crane become in contact with power lines while setting trusses, exposing employees to electrocution hazards.
Recent events (2)
  • — I (O) $660
  • — Z (O) $1100

1926.1412 E01

Other-than-serious 1 instance 1 exposed
Issued
Jul 8, 2016
Abate by
Aug 24, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.1412(e)(1): The equipment in service was not inspected each month in accordance with paragraph (d) of this section (each shift):    a. On or about April 29, 2016, on the east side of the residential building, employees rigging, hooking wood roofing trusses and operating a crane were exposed to struck-by hazard because the employer did not perform, document and maintain monthly crane inspections.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Cinega Custom Framing and Design, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341454015.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.