Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,871Inspections Most recent open 2026-07-30 Last loaded 2026-08-03

OSHA Inspection: EVERGREEN SYNERGIES, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of EVERGREEN SYNERGIES, LLC in 221 KING MANOR SR. STE. D, KING OF PRUSSIA, PA 19406 (NAICS 325611). OSHA activity number 341458537.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Evergreen Synergies, LLC for free Get an email when a new federal OSHA severe-injury report for Evergreen Synergies, LLC is published. One employer, no account, unsubscribe in one click.
Site address
221 KING MANOR SR. STE. D
City
KING OF PRUSSIA
State
PA
ZIP
19406
Mailing
221 KING MANOR SR. STE. D, KING OF PRUSSIA, PA 19406
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325611
Employees
10
Ownership type
A

13 citations on file for this inspection.

1910.303 B06

Serious Gravity 5 1 instance 10 exposed
Issued
Jun 30, 2016
Abate by
Aug 15, 2016
Penalty
Initial $2,400 · Current $2,200 Reduced
29 CFR 1910.303(b)(6): Conductors or equipment were located in damp or wet locations; where exposed to gases, fumes, vapors, liquids, or other agents that had a deteriorating effect on the conductors or equipment; or where exposed to excessive temperatures and were not identified for use in the operating environment:    a) Filling Machine - on or about May 9, 2016, electrical conductors located inside of an open control box was subject to damage from dampness and water condensation, exposing employees to electrical hazards.
Recent events (2)
  • · I (S) $2200
  • · Z (S) $2400

1910.303 G02 I

Serious Gravity 5 1 instance 10 exposed
Issued
Jun 30, 2016
Abate by
Aug 15, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):    a) Filling Machine - on or about May 9, 2016, live electrical conductors operating at greater than 50 volts in an open control box were not guarded against accidental contact.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.305 B01 I

Serious Gravity 5 1 instance 10 exposed
Issued
Jun 30, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings were not protected from abrasions:  a) Filling Machine - on or about May 9, 2016 conductors for the transfer pump entering into an opening for a junction box behind the filling machine were not protected from abrasions and the opening was not effectively closed.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.305 G02 III

Serious Gravity 5 2 instances 10 exposed
Issued
Jun 30, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:  a) Filling Machine, Transfer Pump - on or about May 9, 2016, the flexible cord for the transfer pump had sheathing pulled away from the plug and was not provided strain relief, exposing insulated conductors.   b) Filling Machine, Filler - on or about May 9, 2016, the flexible cord for the filler had sheathing pulled away from the plug and was not provided strain relief, exposing insulated conductors.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.333 B02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 30, 2016
Abate by
Aug 15, 2016
Penalty
Initial $2,400 · Current $2,200 Reduced
29 CFR 1910.333(b)(2)(i): The employer did not maintain a written copy of the procedures outlined in paragraph (b)(2) of 29 CFR 1910.333 and did not make it available for inspection by the Assistant Secretary of Labor and his or her authorized representatives:    a) 221 King Manor Dr. King of Prussia, PA - on or about May 9, 2016, employees were performing work on or near energized parts, but the employer did not have a written copy of the electrical safety related work procedures for lockout and tagging when working.    a) 221 King Manor Dr. King of Prussia, PA - on or about May 9. 2016, employees performed work on and near energized parts, but the employer did not have available a written copy of energy control procedures.
Recent events (2)
  • · I (S) $2200
  • · Z (S) $2400

1910.333 B02 III A

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 30, 2016
Abate by
Aug 15, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.333(b)(2)(iii)(A): A lock and a tag were not placed on each disconnecting means used to deenergize circuits and equipment on which work was to be performed:    a) 221 King Manor Dr. King of Prussia, PA- on or about May 9, 2016, employees performed electrical work to include, but not limited to, splicing conductors, without any locks and tags being placed on each disconnecting means to deenergize circuits and equipment while work was being performed.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

5(a)(1)

Serious Gravity 5 1 instance 6 exposed
Issued
Jun 30, 2016
Abate by
Aug 15, 2016
Penalty
Initial $1,600 · Current $1,300 Reduced
OSH ACT of 1970 Section (5)(a)(1): Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to potential falling hazards due to modified working surfaces.      a) West end - on or about May 9, 2016, employees used a mobile ladder stand to access the second floor mezzanine, but the employer had installed a wood extension placed on the platform to obtain additional height, exposing employees to fall hazards.    Among other methods, one feasible and acceptable method to correct this hazard, is to ensure additional height is not gained by the addition of any type extension or object being placed on the mobile ladder stand in accordance with the American National Standards Institute (ANSI) A14.7, Section 6.7 which states, "Additional height shall not be gained by the addition of any type extension or an object being placed on the unit".
Recent events (2)
  • · I (S) $1300
  • · Z (S) $1600

1910.132 A

Serious Gravity 5 1 instance 6 exposed
Issued
Jun 30, 2016
Penalty
Initial $2,000 · Current $0 Reduced
29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered:    a) Second floor mezzanine - on or about May 9, 2016, employees were retrieving materials from a second floor storage area, with open sided floors in excess of ten feet to the lower level, but were not protected from falling to the lower level by any means of fall protection.
Recent events (2)
  • · I (S) $0
  • · Z (S) $2000

1910.134 C02 I

Other-than-serious 1 instance 2 exposed
Issued
Jun 30, 2016
Abate by
Aug 15, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible:    a) Production Area - on or about May 9, 2016, employees were provided filtering face piece respirators for voluntary use, but the employer had not provided the information contained in Appendix D to 1910.134.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.157 G01

Other-than-serious 1 instance 10 exposed
Issued
Jun 30, 2016
Abate by
Aug 15, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.157(g)(1): An educational program was not provided for all employees to familiarize them with the general principles of fire extinguisher use and the hazards involved with incipient stage firefighting:    a) Throughout Facility, 221 King Manor Dr. - on or about May 9, 2016, the employer had provided portable fire extinguishers throughout the facility, which employees were required to use in the event of a fire, but an educational program had not been provided to familiarize employees with fire extinguisher use.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.1200 E01

Other-than-serious 1 instance 10 exposed
Issued
Jun 30, 2016
Abate by
Aug 15, 2016
Penalty
Initial $1,200 · Current $1,200
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:    a) 221 King Manor Dr. King of Prussia, PA - on or about May 9, 2016, employees manufactured cleaning products with hazardous chemicals contents to include, but not limited to, organic tapioca starch, sodium bicarbonate, chelating agents, and denatured alcohol, but the employer had not developed and implemented a written hazard communication program.
Recent events (2)
  • · I (O) $1200
  • · Z (S) $1200

1910.1200 F06

Other-than-serious 1 instance 10 exposed
Issued
Jun 30, 2016
Abate by
Aug 15, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(f)(6): Except as provided in paragraphs (f)(7) and (f)(8) of this section, the employer shall ensure that each container of hazardous chemicals in the workplace is labeled, tagged, or marked with the information specified under paragraphs (f)(1)(I) through 29 CFR 1910.1200(f)(1)(v):    a) Wash Area - on or about May 9, 2016, employees cleaned equipment with the use of alcohol which was transferred into a workplace container for use, but the employer did not ensure that the container was labeled, tagged, or marked with the information specified under 1910.1200(f)(1)(I) through 1910.1200(f)(1)(v).
Recent events (2)
  • · I (O) $0
  • · Z (S) $0

1910.1200 H01

Other-than-serious 1 instance 10 exposed
Issued
Jun 30, 2016
Abate by
Aug 15, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:    a) 221 King Manor St., King of Prussia, PA - on or about May 9, 2016, employees used chemicals to manufacture cleaning products, but the employer had not provided information and training on the hazardous chemicals used in production and the chemicals used to maintain work areas.
Recent events (2)
  • · I (O) $0
  • · Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341458537.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.