HUBBARDSTON, MA ·
OSHA Inspection: LVIV, INC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of LVIV, INC in 90 NEW TEMPLETON RD, HUBBARDSTON, MA 01452 (NAICS 238160). OSHA activity number 341460681.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LVIV, INC
- Site address
- 90 NEW TEMPLETON RD
- City
- HUBBARDSTON
- State
- MA
- ZIP
- 01452
- Mailing
- 20 SIMPSON ST, STOUGHTON, MA 02072
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 2
- Ownership type
- A
Citations
7 citations on file for this inspection.
1903.19 C01
- Issued
- Sep 7, 2016
- Abate by
- Sep 19, 2016
- Penalty
- Initial $400 · Current $400
General-duty citation text
29 CFR 1903.19(c)(1): The employer did not certify to OSHA, within 10 calendar days after the abatement date, that each cited violation has been abated: As of August 30, 2016, the employer had not certified that the abatement was completed for the violations from Inspection 1146068, issued on 6/2/2016 with a final order date of June 30, 2016.
Recent events (1)
- · Z (O) $400
1903.19 D01
- Issued
- Sep 7, 2016
- Abate by
- Sep 19, 2016
- Penalty
- Initial $400 · Current $400
General-duty citation text
29 CFR 1903.19(d)(1): The employer did not submit to the Agency, along with the information on abatement certification required by paragraph (c)(3) of this section, documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required: As of August 30, 2016, the employer had not submitted documentation demonstrating that the abatement was completed for the violations from Inspection 1146068, issued on 6/2/2016 with a final order date of June 30, 2016.
Recent events (1)
- · Z (O) $400
1926.403 B02
- Issued
- Jun 2, 2016
- Abate by
- Jun 8, 2016
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, and/or certified equipment was not installed and/or used in accordance with instructions included in the listing, labeling, and/or certification: a) 90 New Templeton Rd., Hubbardston, MA: On or May 9, 2016, an employee was using an extension cord contrary to the instructions attached to the cord by plugging it into another extension cord to draw power instead of a mounted receptacle.
Recent events (1)
- · Z (S) $1200
1926.501 B13
- Issued
- Jun 2, 2016
- Abate by
- Jun 8, 2016
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.501(b)(13):Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, or personal fall arrest system: a) 90 New Templeton Rd., Hubbardston, MA: On or May 9, 2016, an employee was roofing this residence without any fall protection more than 17 feet above the lower level/ground. Specific abatement documentation that this violation has been corrected must be provided within 10 days of the abatement in accordance with 29 CFR 1903.19(d)(1).
Recent events (1)
- · Z (S) $2800
1926.1053 B01
- Issued
- Jun 2, 2016
- Abate by
- Jun 8, 2016
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access: a) 90 New Templeton Rd., Hubbardston, MA: On or May 9, 2016, an employee was using an extension ladder, to reach his roof top work location, that did not extend the required 3 feet past the upper landing surface.
Recent events (1)
- · Z (S) $2000
1926.1053 B12
- Issued
- Jun 2, 2016
- Abate by
- Jun 8, 2016
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.1053(b)(12): Ladders did not have nonconductive side rails when they were used where the employee or the ladder could contact exposed energized electrical equipment: a) 90 New Templeton Rd., Hubbardston, MA: On or May 9, 2016, an employee was using an aluminum extension ladder that was supporting an aluminum ladder jack scaffold system that was immediately adjacent to the unprotected electrical service wires for this residence. Specific abatement documentation that this violation has been corrected must be provided within 10 days of the abatement in accordance with 29 CFR 1903.19(d)(1).
Recent events (1)
- · Z (S) $2800
1926.1053 B16
- Issued
- Jun 2, 2016
- Abate by
- Jun 8, 2016
- Penalty
- Initial $1,200 · Current $1,200
General-duty citation text
29 CFR 1926.1053(b)(16): Portable ladders with structural defects were not withdrawn from service until repaired: a) 90 New Templeton Rd., Hubbardston, MA: On or May 9, 2016, an employee was using an aluminum extension ladder with a split rung.
Recent events (1)
- · Z (S) $1200
More inspections in this industry (NAICS 238160)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341460681.