OSHA Inspection: AUTONEUM NORTH AMERICA, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of AUTONEUM NORTH AMERICA, INC. in 480 W 5TH STREET, BLOOMSBURG, PA 17815 (NAICS 314110). OSHA activity number 341461200.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Autoneum North America, INC. for free Get an email when a new federal OSHA severe-injury report for Autoneum North America, INC. is published. One employer, no account, unsubscribe in one click.
Site address
480 W 5TH STREET
City
BLOOMSBURG
State
PA
ZIP
17815
Mailing
480 W 5TH STREET, BLOOMSBURG, PA 17815
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
314110
Employees
700
Ownership type
Private (A)

5 citations on file for this inspection.

1910.212 A01

Serious Gravity 1 1 instance 1 exposed
Issued
Jun 30, 2016
Penalty
Initial $2,250 · Current $1,688 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  a) Dye Line Cutting Station: The unguarded portion of the cutter/ slitter exposed the operator to injury from the rotating parts of the spindle and blades, on or about May 12, 2016.  CORRECTED DURING INSPECTION CERTIFICATION NOT REQUIRED
Recent events (2)
  • · I (S) $1687.5
  • · Z (S) $2250

1910.219 C02 I

Serious Gravity 1 1 instance 1 exposed
Issued
Jun 30, 2016
Penalty
Initial $2,250 · Current $1,688 Reduced
29 CFR 1910.219(c)(2)(i): All exposed parts of horizontal shafting seven (7) feet or less from floor or working platform, excepting runways used exclusively for oiling, or running adjustments, were not protected by a stationary casing enclosing shafting completely or by a trough enclosing sides and top or sides and bottom of shafting as location requires:  a) Extrusion Line: An unguarded rotating shaft between a pneumatic motor and the scrap rollers exposed employees to an entanglement hazard, on or about May 10, 2016.  CORRECTED DURING INSPECTION CERTIFICATION NOT REQUIRED
Recent events (2)
  • · I (S) $1687.5
  • · Z (S) $2250

1910.219 D01

Serious Gravity 1 1 instance 1 exposed
Issued
Jun 30, 2016
Penalty
Initial $2,250 · Current $1,688 Reduced
29 CFR 1910.219(d)(1): Pulleys, with parts which were less than seven (7) feet from the floor or working platform, were not guarded in accordance with the standards specified in paragraphs (m) and (o) of this section:  a) Tool & Die Shop: The drive pulleys on the Fosdick 13 inch drill press were not fully enclosed by a guard exposing the operator to an in-running nip point hazard, on or about May 16, 2016.  CORRECTED DURING INSPECTION CERTIFICATION NOT REQUIRED
Recent events (2)
  • · I (S) $1687.5
  • · Z (S) $2250

1910.219 E03 I

Serious Gravity 1 1 instance 1 exposed
Issued
Jun 30, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(3)(i): Vertical and inclined belts were not enclosed by a guard conforming to standards in paragraphs (m) and (o) of this section:  a) Tool & Die Shop: The drive belts on the Fosdick 13 inch drill press were not fully enclosed by a guard exposing the operator to the runs of the belt, on or about May 16, 2016.  CORRECTED DURING INSPECTION CERTIFICATION NOT REQUIRED
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.303 B02

Serious Gravity 1 1 instance 1 exposed
Issued
Jun 30, 2016
Penalty
Initial $2,250 · Current $1,688 Reduced
29 CFR 1910.303(b)(2): Listed or labeled equipment was not installed and used in accordance with any instructions included in the listing or labeling:  a) Fluid Dye Station: A pair of relocatable power taps that had been daisy-chained together and connected to an extension cord were not properly installed exposing a worker to an electric shock and fire hazard, on or about May 10, 2016.  CORRECTED DURING INSPECTION CERTIFICATION NOT REQUIRED