Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,991Inspections Most recent open 2026-08-24 Last loaded 2026-08-27

OSHA Inspection: D. CRUZ CONSTRUCTION, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of D. CRUZ CONSTRUCTION, LLC in 3901 / 3905 WEST MAIN ROAD, EMMAUS, PA 18049 (NAICS 238160). OSHA activity number 341465029.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch D. Cruz Construction, LLC for free Get an email when a new federal OSHA severe-injury report for D. Cruz Construction, LLC is published. One employer, no account, unsubscribe in one click.
Site address
3901 / 3905 WEST MAIN ROAD
City
EMMAUS
State
PA
ZIP
18049
Mailing
1020 MAIN STREET, HELLERTOWN, PA 18055
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
7
Ownership type
Private (A)

5 citations on file for this inspection.

1926.28 A

Serious Gravity 5 1 instance 3 exposed
Issued
Jun 2, 2016
Penalty
Initial $1,600 · Current $1,600
29 CFR 1926.28(a): The employer did not require the wearing of appropriate personal protective equipment in all operations where there is an exposure to hazardous conditions:  a) 3901 / 3905 West Main Road, Vera Cruz, PA, Worksite - on or about May 10, 2016, employees were receiving roofing materials being lifted to the working height by a knuckle boom loader truck, which creates an overhead strike hazard, but the employees were not wearing any type of head protection.
Recent events (1)
  • · Z (S) $1600

1926.501 B13

Serious Gravity 10 1 instance 3 exposed
Issued
Jun 2, 2016
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b):  a) 3901 / 3905 West Main Road, Vera Cruz, PA, Worksite, Roof - on or about May 10, 2016, employees were performing residential roofing work, between eight and approximately 23 feet above grade, without utilizing any means of fall protection.
Recent events (1)
  • · Z (S) $2800

1926.1053 B01

Serious Gravity 10 1 instance 3 exposed
Issued
Jun 2, 2016
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:  a) 3901 / 3905 West Main Road, Vera Cruz, PA, Worksite - on or about May 10, 2016, employees were performing residential roofing work while using portable ladder sections to access the upper working surfaces, but each ladder section did not extend at least three feet above the upper landing surface being accessed.
Recent events (1)
  • · Z (S) $2800

1926.1053 B05 I

Serious Gravity 10 1 instance 3 exposed
Issued
Jun 2, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladders were not used at an angle such than the horizontal distance from the top support to the foot of the ladder way approximately one-quarter of the working length of the ladder, which is the distance along the ladder between the foot and the top support:  a) 3901 / 3905 West Main Road, Vera Cruz, PA, Worksite - on or about May 10, 2016, employees were performing residential roofing work while using a portable ladder base section set on a porch to access the upper working surface, but this ladder section was set at an angle greater than one-quarter of the working length of the ladder.
Recent events (1)
  • · Z (S) $0

1926.1053 B06

Serious Gravity 10 1 instance 3 exposed
Issued
Jun 2, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(6): Unsecured ladder(s) were used on surfaces that were not stable and level:  a) 3901 / 3905 West Main Road, Vera Cruz, PA, Worksite - on or about May 10, 2016, employees were performing residential roofing work while using a portable extension ladder base section set on a porch roof to access the uppermost working surface, but this ladder section was set on a 4 in 12 pitched surface and was not secured to prevent displacement.
Recent events (1)
  • · Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 341465029.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.