Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: GARTNER COATINGS, INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of GARTNER COATINGS, INC. in 2433 MAX RD, PEARLAND, TX 77581 (NAICS 332812). OSHA activity number 341465094.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Gartner Coatings, INC. for free Get an email when a new federal OSHA severe-injury report for Gartner Coatings, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2433 MAX RD
City
PEARLAND
State
TX
ZIP
77581
Mailing
2433 MAX RD, PEARLAND, TX 77581
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332812
Employees
45
Ownership type
Private (A)

9 citations on file for this inspection.

1910.107 B05 IV

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 22, 2016
Abate by
Sep 26, 2016
Penalty
Initial $4,240 · Current $2,120 Reduced
29 CFR 1910.107(b)(5)(iv): Space within the spray booth on the downstream and upstream sides of filters were not protected with approved automatic sprinklers:    (a)  The Powder Coating Booth was not equipped with sprinklers.  Employees spray combustible powder coatings within the booth.
Recent events (2)
  • · I (S) $2120
  • · Z (S) $4240

1910.107 E02

Serious Gravity 5 6 instances 6 exposed
Issued
Aug 22, 2016
Abate by
Sep 1, 2016
Penalty
Initial $4,240 · Current $2,120 Reduced
29 CFR 1910.107(e)(2): The quantity of flammable liquids kept in the vicinity of spraying operations exceeded a supply for 1 day or one shift:    (a)  Two five-gallon containers of methyl ethyl ketone (MEK) and one five-gallon container of waste paint were stored inside Booth #1.    (b)  Two five-gallon containers of methyl ethyl ketone (MEK) and one five-gallon container of waste paint were stored inside Booth #2.
Recent events (2)
  • · I (S) $2120
  • · Z (S) $4240

1910.107 G05

Serious Gravity 5 6 instances 6 exposed
Issued
Aug 22, 2016
Abate by
Sep 1, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.107(g)(5): Solvents with a flashpoint of not less than 100 deg. F. were used for cleaning spray nozzles and auxiliary equipment:  (a)  in Booth #1, Methyl Ethyl Ketone (MEK) was used for cleaning spray nozzles and auxiliary equipment.  The flashpoint of MEK is 16 degrees F.  (b)  in Booth #2, Methyl Ethyl Ketone (MEK) was used for cleaning spray nozzles and auxiliary equipment.  The flashpoint of MEK is 16 degrees F.  (c)  in Booth #3, Methyl Ethyl Ketone (MEK) was used for cleaning spray nozzles and auxiliary equipment.  The flashpoint of MEK is 16 degrees F.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.134 I05 IV

Serious Gravity 5 6 instances 6 exposed
Issued
Aug 22, 2016
Abate by
Sep 1, 2016
Penalty
Initial $5,300 · Current $2,650 Reduced
29 CFR 1910.134(i)(5)(iv): The employer did not ensure that compressors used to supply breathing air to respirators were constructed and situated so as to have a tag maintained at the compressor containing the most recent change date and the signature of the person authorized by the employer to perform the change:    (a)  In building #1, compressors were not tagged with the most recent change date and signature of the person authorized by the employer to perform the change.    (b)  In building #3, compressors were not tagged with the most recent change date and signature of the person authorized by the employer to perform the change.
Recent events (2)
  • · I (S) $2650
  • · Z (S) $5300

1910.95 G06

Other-than-serious 6 instances 6 exposed
Issued
Aug 22, 2016
Penalty
Initial $900 · Current $450 Reduced

Hazardous substances 8110

29 CFR 1910.95(g)(6): At least annually after obtaining the baseline audiogram, the employer did not obtain a new audiogram for each employee exposed at or above an 8-hour time-weighted average of 85 decibels:    (a)  In Blast Booth #1, an abrasive blaster had not received the annual audiogram.  The abrasive blaster was exposed to 91.0 dBA. Sampling was conducted for 90 minutes on May 20, 2016. Zero exposure was assumed for the remaining 390 minutes.    (a)  In Blast Booth #1, an abrasive blaster had not received the annual audiogram.  The abrasive blaster was exposed to 97.4 dBA. Sampling was conducted for 218 minutes on June 30, 2016. Zero exposure was assumed for the remaining 262 minutes.
Recent events (2)
  • · I (O) $450
  • · Z (O) $900

1910.1000 A02

Other-than-serious 6 instances 6 exposed
Issued
Aug 22, 2016
Abate by
Feb 21, 2017
Penalty
Initial $1,059 · Current $530 Reduced

Hazardous substances 9030

29 CFR 1910.1000(a)(2): Employee(s) were exposed to an airborne concentration of particulate not otherwise regulated (respirable fraction) listed in Table Z-1 in excess of the 8 hour Time Weighted Average concentration of 5.0 milligrams per cubic meter:    (a)  In the Powder Coating Booth, where an employee performing powder coating activities was exposed to respirable dust at an 8-hour time-weighted average (TWA) of 10.6 milligrams per cubic meter, 2.1 times the permissible exposure limit (PEL) for respirable dust of 5 milligrams per cubic meter.  Sampling was conducted for 212 minutes on June 30, 2016. Zero exposure was assumed for the remaining 268 minutes.
Recent events (2)
  • · I (O) $530
  • · Z (O) $1059

1910.107 B05 I

Other-than-serious 1 instance 6 exposed
Issued
Aug 22, 2016
Abate by
Sep 1, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.107(b)(5)(i): The average air speed over the open face of the paint spray booth was less than 100 linear feet per minute:  (a)  In the Powder Coating Booth, the average air speed over the open face to the paint spray booth was less than 5 linear feet per minute.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.1000 B01

Other-than-serious 6 instances 6 exposed
Issued
Aug 22, 2016
Abate by
Feb 21, 2017
Penalty
Initial $0 · Current $0

Hazardous substances 9010

29 CFR 1910.1000(b)(1): Employee(s) were exposed to an airborne concentration of crystalline silica listed in Table Z-2 in excess of the 8 hour Time Weighted Average:  (a)  In Blast Booth #1, where an employee performing abrasive blasting with Garnet was exposed to respirable dust containing 1.6% crystalline quartz at an 8-hour time-weighted average (TWA) of 5.5 milligrams per cubic meter.  The permissible exposure limit (PEL) for respirable dust containing 1.6% crystalline quartz is 2.797 milligrams per cubic meter.  The employee's exposure was 1.9 times the PEL.  Sampling was conducted for 267 minutes on May 23, 2016. Zero exposure was assumed for the remaining 213 minutes.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.1000 E

Other-than-serious 2 instances 8 exposed
Issued
Aug 22, 2016
Abate by
Feb 21, 2017
Penalty
Initial $0 · Current $0

Hazardous substances 90109130

29 CFR 1910.1000(e): Feasible administrative or engineering controls were not determined and implemented to achieve compliance with the limits prescribed in 29 CFR 1910.1000(a) through (d):  (a)  In the Powder Coating Booth, where an employee performing powder coating activities was exposed to respirable dust at an 8-hour time-weighted average (TWA) of 10.6 milligrams per cubic meter, 2.1 times the permissible exposure limit (PEL) for respirable dust of 5 milligrams per cubic meter.  Sampling was conducted for 212 minutes on June 30, 2016. Zero exposure was assumed for the remaining 268 minutes.  (b)  In Blast Booth #1, where an employee performing abrasive blasting with Garnet was exposed to respirable dust containing 1.6% crystalline quartz at an 8-hour time-weighted average (TWA) of 5.5 milligrams per cubic meter.  The permissible exposure limit (PEL) for respirable dust containing 1.6% crystalline quartz is 2.797 milligrams per cubic meter.  The employee's exposure was 1.9 times the PEL.  Sampling was conducted for 267 minutes on May 23, 2016. Zero exposure was assumed for the remaining 213 minutes.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View Gartner Coatings, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 341465094.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.