ASHLAND CITY, TN ·
OSHA Inspection: ROYAL BRIDGE, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ROYAL BRIDGE, INC. in 1798 CHEATHAM DAM ROAD, ASHLAND CITY, TN 37015 (NAICS 236220). OSHA activity number 341466720.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ROYAL BRIDGE, INC.
- Site address
- 1798 CHEATHAM DAM ROAD
- City
- ASHLAND CITY
- State
- TN
- ZIP
- 37015
- Mailing
- 3601 ALT 19 NORTH, PALM HARBOR, FL 34683
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 21
- Ownership type
- A
Citations
9 citations on file for this inspection.
1926.300 B01
- Issued
- Jun 3, 2016
- Abate by
- Jun 15, 2016
- Penalty
- Initial $1,785 · Current $1,071 Reduced
General-duty citation text
29 CFR 1926.300(b)(1): Power operated tool(s), designed to accommodate guards, were not equipped with such guards when in use: a) Welding Shop - On or about 5/11/16, employees were exposed to struck-by hazards when the angle grinder was not equipped with the guard. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- · I (S) $1071
- · Z (S) $1785
1926.300 B02
- Issued
- Jun 3, 2016
- Abate by
- Jun 15, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.300(b)(2): Moving part(s) of equipment exposed to contact by employees or which otherwise created a hazard, were not guarded: a) Welding Shop - On or about 5/11/16, the horizontal band saw was not guarded properly to prevent contact with the blade. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.303 C01
- Issued
- Jun 3, 2016
- Abate by
- Jun 15, 2016
- Penalty
- Initial $1,785 · Current $1,071 Reduced
General-duty citation text
29 CFR 1926.303(c)(1): Floor stand or bench mounted abrasive wheel(s), used for external grinding, were not provided with safety guards (protection hoods): a) Barge - On or about 5/11/16 employees were exposed to struck-by hazards when the bench grinder was not equipped with a tongue guard . In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- · I (S) $1071
- · Z (S) $1785
1926.303 C02
- Issued
- Jun 3, 2016
- Abate by
- Jun 22, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.303(c)(2): Floor or bench mounted grinder(s) were not provided with work rests: a) Barge - On or about 5/11/16, employees were exposed to struck-by hazards when the bench grinder was not equipped with work rests. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.350 A07
- Issued
- Jun 3, 2016
- Penalty
- Initial $2,380 · Current $1,428 Reduced
General-duty citation text
29 CFR 1926.350(a)(7): A suitable cylinder truck, chain, or other steadying device was not used to keep compressed gas cylinder(s) from being knocked over while in use: a) Barge - On or about 5/11/16, employees were exposed to struck-by hazards when acetylene cylinders were not secured to prevent from tipping over. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- · I (S) $1428
- · Z (S) $2380
1910.134 H02 I
- Issued
- Jun 3, 2016
- Abate by
- Jun 15, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(h)(2)(i): Respirators were not stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals or were not packed or stored to prevent deformation of the facepiece and exhalation valve: (Construction Reference 1926.103) a) Cheatham Dam - On or about 5/11/16, respirators were not stored to prevent contamination. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- · I (O) $0
- · Z (O) $0
1926.404 F06
- Issued
- Jun 3, 2016
- Abate by
- Jun 15, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: a) Cheatham Dam- On or about 5/11/16, employees were exposed to electrical hazards when the ground prong on an extension cord was missing. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- · I (O) $0
- · Z (O) $0
1926.405 E01
- Issued
- Jun 3, 2016
- Abate by
- Jun 15, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(e)(1): Cabinets, cutout boxes, fittings, boxes, and panelboard enclosures in damp or wet locations were not installed so as to prevent moisture or water from entering and accumulating within the enclosures: a) Barge- On or about 5/11/16, employees were exposed to electrical hazards when an outside outlet was not protected against water accumulation in that it was missing the cover. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- · I (O) $0
- · Z (O) $0
1926.405 G02 IV
- Issued
- Jun 3, 2016
- Abate by
- Jun 15, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: (a) Barge - On or about 5/11/16, strain relief was not provided on the power cord for the bench grinder. In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections at Royal Bridge, INC.
View Royal Bridge, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 236220)
More inspections in TN
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341466720.