Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: F&S INTERIORS INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of F&S INTERIORS INC. in 333 KELLY PARKWAY, CASCADE, ID 83611 (NAICS 238310). OSHA activity number 341467595.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch F&S Interiors INC. — free Get an email when a new federal OSHA severe-injury report for F&S Interiors INC. is published. One employer, no account, unsubscribe in one click.
Establishment
F&S INTERIORS INC.
Site address
333 KELLY PARKWAY
City
CASCADE
State
ID
ZIP
83611
Mailing
120 E 46TH STREET, BOISE, ID 83714
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238310
Employees
15
Ownership type
A

2 citations on file for this inspection.

1926.405 G02 IV

Serious Gravity 10 1 instance 1 exposed
Issued
Jul 25, 2016
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws:    (a) On or about May 11, 2016 and at times prior thereto employees were exposed to electrical hazards when internal wiring was exposed on an extension cord directly behind the plug, where the cord was being used by employees to provide power to portable lights.    NOTE- Abatement certification and documentation are required for this item.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1926.405 J01 I

Serious Gravity 10 3 instances 2 exposed
Issued
Jul 25, 2016
Abate by
Jul 29, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.405(j)(1)(i): Fixtures, lampholders, lamps, rosettes, or receptacles had live parts normally exposed to employee contact:  (a) On or about May 11, 2016 and at times prior thereto employees were exposed to electrical hazards when internal wiring was exposed on outlets and a light switch which had no cover plates, while power was applied, where drywall employees were applying drywall compound (mud) next to the outlets, and a light switch with hand held tools.  NOTE- Abatement certification and documentation are required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View F&S Interiors INC.'s full OSHA safety record →