Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SOFCO ERECTORS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SOFCO ERECTORS, INC. in 1011 CLEVELAND AVENUE, COLUMBUS, OH 43201 (NAICS 238120). OSHA activity number 341468536.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Sofco Erectors, INC. — free Get an email when a new federal OSHA severe-injury report for Sofco Erectors, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1011 CLEVELAND AVENUE
City
COLUMBUS
State
OH
ZIP
43201
Mailing
10360 WAYNE AVENUE, CINCINNATI, OH 45215
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238120
Employees
128
Ownership type
A

2 citations on file for this inspection.

1926.453 B02 V

Serious Gravity 5 2 instances 4 exposed
Issued
Jul 8, 2016
Abate by
Jul 20, 2016
Penalty
Initial $3,825 · Current $1,910 Reduced
29 CFR 1926.453(b)(2)(v): A body belt shall be worn and a lanyard attached to the boom or basket when working from an aerial lift.  Note to paragraph (b)(2)(v): As of January 1, 1998, subpart M of this part (1926.502(d)) provides that body belts are not acceptable as part of a personal fall arrest system. The use of a body belt in a tethering system or in a restraint system is acceptable and is regulated under 1926.502(e).    a. On or before May 12, 2016 where employees were working from the elevated platforms of aerial lifts, the employees did not connect their fall protection harnesses to the anchor points of the platforms, thereby being exposed to fall hazards of fifteen feet.
Recent events (2)
  • — I (S) $1910
  • — Z (S) $3825

1926.760 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 8, 2016
Abate by
Jul 20, 2016
Penalty
Initial $3,825 · Current $1,910 Reduced
29 CFR 1926.760(a)(1): Except as provided by paragraph (a)(3) of this section, each employee engaged in a steel erection activity who is on a walking/working surface with an unprotected side or edge more than 15 feet (4.6 m) above a lower level shall be protected from fall hazards by guardrail systems, safety net systems, personal fall arrest systems, positioning device systems or fall restraint systems.    a. On or before May 12, 2016 where employees were landing decking on the joists between the first and second floors, the employees were not protected from falls, thereby being exposed to a 16 foot, 8 inch fall hazard.
Recent events (2)
  • — I (S) $1910
  • — Z (S) $3825

View Sofco Erectors, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341468536.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.