SELINSGROVE, PA —
OSHA Inspection: ARCON GROUP, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of ARCON GROUP, INC. in 195 AIRPORT ROAD, SELINSGROVE, PA 17870 (NAICS 321991). OSHA activity number 341469765.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ARCON GROUP, INC.
- Site address
- 195 AIRPORT ROAD
- City
- SELINSGROVE
- State
- PA
- ZIP
- 17870
- Mailing
- 195 AIRPORT ROAD, SELINSGROVE, PA 17870
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321991
- Employees
- 80
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.23 C01
- Issued
- Jul 14, 2016
- Abate by
- Aug 30, 2016
- Penalty
- Initial $2,800 · Current $2,500 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards: a) Plant #1: The ceiling jig platform, which was installed 35 inches above the floor of an 8-foot high mezzanine, was not guarded to protect employees from an 11 foot fall hazard, on or about May 12, 2016. ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- — F (S) $2500
- — C (S) $2800
- — Z (S) $2800
1910.23 E01
- Issued
- Jul 14, 2016
- Abate by
- Aug 30, 2016
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1910.23(e)(1): Standard railing(s) did not consist of top rail, intermediate rail and/or posts and/or did not have a vertical height of 42 inches (106.7 cm) nominal from upper surface of top rail to floor, platform runway, or ramp level: a) Plant #1: The top rail on the wall jig platform was only at a height of 33 inches exposing employees to a fall of approximately 6 feet, on or about May 12, 2016. ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- — F (S) $0
- — C (S) $2800
- — Z (S) $2800
1910.23 D01
- Issued
- Jul 14, 2016
- Abate by
- Aug 30, 2016
- Penalty
- Initial $2,100 · Current $0 Reduced
General-duty citation text
29 CFR 1910.23(d)(1): Every flight of stairs having four or more risers was not equipped with standard stair railings or standard handrails as specified in paragraphs (d)(1)(i) through (v) of this section, the width of the stair to be measured clear of all obstructions except handrails: a) Plant #1: A set of stairs leading up to the ceiling jig platform which had four (4) risers was not equipped with standard railings on each open side exposing employees to a fall, on or about May 12, 2016. ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- — F (S) $0
- — C (S) $2100
- — Z (S) $2100
1910.179 L03 III D
- Issued
- Jul 14, 2016
- Abate by
- Aug 30, 2016
- Penalty
- Initial $2,100 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.179(l)(3)(iii)(d): Pendant control stations were not kept clean, and/or their function labels were not kept legible: a) Plant #1: The pendant control for the 2-ton overhead crane used to lift ceiling components was not maintained in a clean condition with legible control function labels, on or about May 12, 2016. ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- — F (S) $2000
- — C (S) $2100
- — Z (S) $2100
1910.213 S09
- Issued
- Jul 14, 2016
- Abate by
- Jul 26, 2016
- Penalty
- Initial $3,500 · Current $2,150 Reduced
General-duty citation text
29 CFR 1910.213(s)(9): Suitable sizes and types of push sticks or push blocks were not provided at the work place: a) Plant #1: Push sticks were not available for use by an employee operating a table saw to cut strips of drywall, on or about May 12, 2016. ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- — F (S) $2150
- — C (S) $3500
- — Z (S) $3500
1910.141 D01
- Issued
- Jul 14, 2016
- Abate by
- Aug 30, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.141(d)(1): General. Washing facilities shall be maintained in a sanitary condition: a) Plant #1: The toilets and floor in the women's restroom were not maintained in a clean and sanitary condition, on or about May 12, 2016. b) Plant #2: The toilets and floor in the men's restroom were not maintained in a clean and sanitary condition, on or about May 19, 2016. ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
1910.141 C02 I
- Issued
- Jul 14, 2016
- Abate by
- Aug 30, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.141(c)(2)(i): Each water closet did not occupy a separate compartment with a door and walls or partitions between fixtures sufficiently high to assure privacy: Plant #1: The toilets in the woman's restroom were not separated by a partition assuring privacy, on or about May 12, 2016. ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
1910.178 L01 II
- Issued
- Jul 14, 2016
- Abate by
- Aug 30, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(1)(ii): The employer did not ensure that each operator had successfully completed the training required by paragraph (l), except as permitted by paragraph (l)(5), prior to permitting an employee to operate a powered industrial truck: a) Plant #1: An employee had not received training prior to being assigned to operate a Clark C500 forklift, on or about May 12, 2016. ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
1910.178 Q07
- Issued
- Jul 14, 2016
- Abate by
- Aug 30, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(q)(7): Industrial trucks were not examined before being placed in service: a) Plant #1: The employer's three (3) forklifts and one (1) tractor are used daily without first being examined to ensure a safe operating condition, on or about May 12, 2016. ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
More inspections at Arcon Group, INC.
View Arcon Group, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 321991)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341469765.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.