Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SCHNEIDER ELECTRIC & PLUMBING

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SCHNEIDER ELECTRIC & PLUMBING in LOT 412 SIENNA ST NW, MASSILLON, OH 44646 (NAICS 238910). OSHA activity number 341469948.

Watch Schneider Electric & Plumbing — free Get an email when a new federal OSHA severe-injury report for Schneider Electric & Plumbing is published. One employer, no account, unsubscribe in one click.
Site address
LOT 412 SIENNA ST NW
City
MASSILLON
State
OH
ZIP
44646
Mailing
7762 TOWNSHIP ROAD 671, WINESBURG, OH 44690
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238910
Employees
5
Ownership type
A

2 citations on file for this inspection.

1926.651 C02

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $2800.00 · Current $1680.00 Reduced
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees:     On or about May 12, 2016, at a job-site located at Lot 412 Sienna St NW, Massillon, Ohio 44646, the employer did not ensure adequate means of access and or egress for an employee engaged in work in a trench greater than 4 feet deep. An employee was working inside a trench with near vertical side walls and a depth of approximately 13 feet.  The trench was determined to have type "C" soil.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1926.652 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $2800.00 · Current $1680.00 Reduced
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(c).      On or about May 12, 2016, at a job-site located at Lot 412 Sienna St NW, Massillon, Ohio 44646, the employer did not ensure adequate cave-in protection was used to protect an employee working inside a trench with near vertical side walls and a depth of approximately 13 feet.  The trench was determined to have type "C" soil.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341469948.