Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: D & B ERECTORS, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of D & B ERECTORS, LLC in 14876 NARCOOSSEE RD., ORLANDO, FL 32832 (NAICS 238190). OSHA activity number 341470235.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch D & B Erectors, LLC — free Get an email when a new federal OSHA severe-injury report for D & B Erectors, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
D & B ERECTORS, LLC
Site address
14876 NARCOOSSEE RD.
City
ORLANDO
State
FL
ZIP
32832
Mailing
727 ROCKMART RD, BUCHANAN, GA 30113
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238190
Employees
6
Ownership type
A

1 citation on file for this inspection.

1926.760 A01

Serious Gravity 10 2 instances 5 exposed
Issued
Jun 29, 2016
Penalty
Initial $2,800 · Current $1,680 Reduced
29 CFR 1926.760(a)(1): Each employee engaged in a steel erection activity who is on a walking/working surface with an unprotected side or edge more than 15 feet (4.6 m) above a lower level was not protected from fall hazards by guardrail systems, safety net systems, personal fall arrest systems, positioning device systems, or fall restraint systems.  a. On or about 05/09/2016, at the job site - an employee installing metal flashing and caulking at the edge the roof of a gas station canopy fell about 16 feet 5 inch to the ground after tripping on the flashing. The employee was wearing a harness but was not connected.    b. On or about 05/12/2016, at the job site - employees installing metal roofing, flashing and caulking from the roof of a gas station canopy were exposed to about 16 feet 5 inch to 25 feet 3 inch from the edge of the roof to the ground, in that, their harnesses were not connected.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

View D & B Erectors, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341470235.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.