Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,193,745Inspections Most recent open 2026-08-06 Last loaded 2026-08-10

OSHA Inspection: FIVE STAR SOLUTIONS CORP.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of FIVE STAR SOLUTIONS CORP. in YATES VILLAGE -- BUILDING G 2450 VAN VRANKEN AVE, SCHENECTADY, NY 12308 (NAICS 238160). OSHA activity number 341472082.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Five Star Solutions Corp. for free Get an email when a new federal OSHA severe-injury report for Five Star Solutions Corp. is published. One employer, no account, unsubscribe in one click.
Site address
YATES VILLAGE -- BUILDING G 2450 VAN VRANKEN AVE
City
SCHENECTADY
State
NY
ZIP
12308
Mailing
121 SANDBURG PLACE, PINE BUSH, NY 12566
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
6
Ownership type
A

6 citations on file for this inspection.

1926.102 A01

Serious Gravity 1 1 instance 6 exposed
Issued
May 24, 2016
Penalty
Initial $1,200 · Current $1,200
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents.  (a) Yates village building G, during roof tear-off and repair:  On or about 5/11/16, employees did not use protective eyeware (safety glasses) for protection from flying debris.
Recent events (2)
  • · I (S) $1200
  • · Z (S) $1200

1926.404 B01 II

Serious Gravity 5 2 instances 6 exposed
Issued
May 24, 2016
Abate by
Jun 1, 2016
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupers for personal protection.    (a)  Yates village building G, during roof tear-off and repair:  On or about 5/11/16, extension cord used to power a porter-cable pancake compressor was not used with GFCI protection, exposing employees to a potential shock hazard.  Cord was connected to a 120V receptacle inside the mechanical room of the building.    (b) Yates village building G, during roof tear-off and repair:  On or about 5/11/16, extension cord used to power a circular saw on the roof deck was not used with GFCI protection, exposing employees to a potential shock hazard.  Cord was connected to a 120V receptacle inside a vacant apartment.
Recent events (2)
  • · I (S) $1200
  • · Z (S) $2000

1926.502 D15

Serious Gravity 10 5 instances 4 exposed
Issued
May 24, 2016
Penalty
Initial $2,800 · Current $1,200 Reduced
29 CFR 1926.502(d)(15): Anchorages used for attachment of personal fall arrest equipment were not independent of any anchorage being used to support or suspend platforms and/or were not capable of supporting at least 5,000 pounds (22.2 kN) per employee attached:      (a) Yates village building G, during roof tear-off and repair:  On or about 5/11/16, anchor points for vertical lifelines were not secured with the required number of 12d nails which increases the probability of anchor point failure in a fall arrest or fall restraint event.   Employees were exposed to a fall hazard of 18 to 20' to ground level.
Recent events (2)
  • · I (S) $1200
  • · Z (S) $2800

1926.503 A02 III

Serious Gravity 10 1 instance 3 exposed
Issued
May 24, 2016
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1926.503(a)(2)(iii): The employer did not assure that each employee has been trained, as necessary, by a competent person in the use and operation of guardrail systems, safety net systems, warning line systems, safety monitoring systems, controlled access zones, and other protection to be used.    (a) Yates village building G, during roof tear-off and repair:  On or about 5/11/16, employees using vertical lifelines and rope grabs for fall protection were not trained in the safe use of the Guardian fall protection equipment, including but not limited to:      -- Remaining connected to the lifeline at all times while on the roof deck     -- Proper installation of the lifeline anchor point with the required number of nails    -- Attaching only one snaphook to the anchor point at a time    -- Adjustment of the rope grab to keep excess slack out of the rope and work position to minimize swing falls      Employees were exposed to a fall hazard of 18 to 20' to ground level.
Recent events (2)
  • · I (S) $0
  • · Z (S) $2800

1926.416 E01

Other-than-serious 1 instance 5 exposed
Issued
May 24, 2016
Abate by
Jun 1, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used:  (a) On or about 5/11/16, extension cord used to power a circular saw on the roof deck had cuts and tears in the outer jacket.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1926.503 B01

Other-than-serious 1 instance 3 exposed
Issued
May 24, 2016
Abate by
Jun 1, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer.  (a) Yates village building G, during roof tear-off and repair:  On or about 5/11/16, the employer did not certify that workers using vertical lifelines and rope grabs for fall protection were trained in the safe use of the Guardian fall protection equipment, including but not limited to:    -- Remaining connected to the lifeline at all times while on the roof deck   -- Proper installation of the lifeline anchor point with the required number of nails  -- Attaching only one snaphook to the anchor point at a time  -- Adjustment of the rope grab to keep excess slack out of the rope and work position to minimize swing falls    Employees were exposed to a fall hazard of 18 to 20' to ground level.
Recent events (2)