SKANEATELES, NY —
OSHA Inspection: FINGER LAKES CUSTOM MANUFACTURING, INC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of FINGER LAKES CUSTOM MANUFACTURING, INC in 816 WEST GENESEE STREET, SKANEATELES, NY 13152 (NAICS 441310). OSHA activity number 341474104.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FINGER LAKES CUSTOM MANUFACTURING, INC
- Site address
- 816 WEST GENESEE STREET
- City
- SKANEATELES
- State
- NY
- ZIP
- 13152
- Mailing
- 816 WEST GENESEE STREET, SKANEATELES, NY 13152
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 441310
- Employees
- 4
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.212 A01
- Issued
- Jun 16, 2016
- Abate by
- Jul 6, 2016
- Penalty
- Initial $1,600 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. a. In the production area, on or about 5/13/16: An Induma milling machine being operated as a drill press was not equipped with point-of-operation guarding. Abatement certification must be submitted for this item.
Recent events (2)
- — I (S) $1200
- — Z (S) $1600
1910.305 G01 IV A
- Issued
- Jun 16, 2016
- Abate by
- Jul 21, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a. Within the facility, on or about 5/13/16: A flexible cord used to power an Induma mill was used as a substitute for the fixed wiring of a structure. Abatement certification must be submitted for this item.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Finger Lakes Custom Manufacturing, INC
View Finger Lakes Custom Manufacturing, INC's full OSHA safety record →
More inspections in this industry (NAICS 441310)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341474104.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.