Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,249Inspections Most recent open 2026-08-20 Last loaded 2026-08-24

OSHA Inspection: SIEMENS ENERGY INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of SIEMENS ENERGY INC. in 5730 CLINTON DRIVE, HOUSTON, TX 77020 (NAICS 221119). OSHA activity number 341478527.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Siemens Energy INC. for free Get an email when a new federal OSHA severe-injury report for Siemens Energy INC. is published. One employer, no account, unsubscribe in one click.
Establishment
SIEMENS ENERGY INC.
Site address
5730 CLINTON DRIVE
City
HOUSTON
State
TX
ZIP
77020
Mailing
5730 CLINTON DRIVE, HOUSTON, TX 77020
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Union (A)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
221119
Employees
245
Ownership type
Private (A)

1 citation on file for this inspection.

1910.212 A03 II

Other-than-serious 6 instances 21 exposed
Issued
Jun 28, 2016
Abate by
Aug 26, 2016
Penalty
Initial $7,000 · Current $7,000
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):    On or about May 18, 2016:        a. In the Coating Department where employees were exposed to struck-by and thermal burn hazards while using a thermal coating booth identified as Booth E001 without an interlocking door guard to protect employees from moving parts and flame while the thermal spray operation was active.           b. In the Coating Department where employees were exposed to struck-by and thermal burn hazards while using a thermal coating booth identified as Booth E002 without an interlocking door guard to protect employees from moving parts and flame while the thermal spray operation was active.          c. In the Coating Department where employees were exposed to struck-by and thermal burn hazards while using a thermal coating booth identified as Booth E054 without an interlocking door guard to protect employees from moving parts and flame while the thermal spray operation was active.          d. In the Coating Department where employees were exposed to struck-by and thermal burn hazards while using a thermal coating booth identified as Booth E055 without an interlocking door guard to protect employees from moving parts and flame while the thermal spray operation was active.          e. In the Coating Department where employees were exposed to struck-by and thermal burn hazards while using a thermal coating booth identified as Booth E056 without an interlocking door guard to protect employees from moving parts and flame while the thermal spray operation was active.       f. In the Coating Department where employees were exposed to thermal burn hazards while using a Pacific Kiln brand Burnout Furnace without an interlocking door guard to protect employees from the heat inside the furnace.
Recent events (2)
  • · I (O) $7000
  • · Z (S) $7000

View Siemens Energy INC.'s full OSHA safety record →