LAKEWOOD, CO —
OSHA Inspection: DILLIGAFF, INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DILLIGAFF, INC in 1612 TELLER ST, LAKEWOOD, CO 80214 (NAICS 811121). OSHA activity number 341481380.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DILLIGAFF, INC
- Site address
- 1612 TELLER ST
- City
- LAKEWOOD
- State
- CO
- ZIP
- 80214
- Mailing
- 1612 TELLER ST, LAKEWOOD, CO 80214
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811121
- Employees
- 11
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.23 C01
- Issued
- Jun 3, 2016
- Abate by
- Jun 29, 2016
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent): a) North and South Mezzanine: On or about May 13, 2016, and at times prior, workers were exposed to falling more than eight feet from upper levels where top rails were installed too low and intermediate rails were not provided. Abatement Note: Abatement certification is required for this item (see enclosed Certification of Corrective Action Worksheet).
Recent events (2)
- — I (S) $1200
- — Z (S) $2000
1910.23 D01
- Issued
- Jun 3, 2016
- Abate by
- Jun 29, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.23(d)(1): Every flight of stairs having four or more risers was not equipped with standard stair railings or standard handrails as specified in paragraphs (d)(1)(i) through (v) of this section, the width of the stair to be measured clear of all obstructions except handrails: a) North and South Mezzanine Stairs: On or about May 13, 2016, and at times prior, workers were exposed to falling from stairways that were not provided with intermediate rails. Abatement Note: Abatement certification is required for this item (see enclosed Certification of Corrective Action Worksheet).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 G02 II
- Issued
- Jun 3, 2016
- Abate by
- Jun 15, 2016
- Penalty
- Initial $1,200 · Current $720 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(ii): In locations where electric equipment was likely to be exposed to physical damage, enclosures or guards were not so arranged and of such strength as to prevent such damage: a) North and South Mezzanine: On or about May 13, 2016, and at times prior, workers were exposed to electrical and other hazards in that the bulbs of fluorescent light fixtures were installed between 51 and 72 inches from the floor near foot-traffic areas. Abatement Note: Abatement certification is required for this item (see enclosed Certification of Corrective Action Worksheet).
Recent events (2)
- — I (S) $720
- — Z (S) $1200
More inspections at Dilligaff, INC
View Dilligaff, INC's full OSHA safety record →
More inspections in this industry (NAICS 811121)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341481380.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.