Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,124Inspections Most recent open 2026-08-25 Last loaded 2026-08-28

OSHA Inspection: C-P CONVERTERS, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of C-P CONVERTERS, INC. in 181 RITTENHOUSE CIRCLE, BRISTOL, PA 19007 (NAICS 326112). OSHA activity number 341482024.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch C-P Converters, INC. for free Get an email when a new federal OSHA severe-injury report for C-P Converters, INC. is published. One employer, no account, unsubscribe in one click.
Site address
181 RITTENHOUSE CIRCLE
City
BRISTOL
State
PA
ZIP
19007
Mailing
181 RITTENHOUSE CIRCLE, BRISTOL, PA 19007
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326112
Employees
98
Ownership type
Private (A)

6 citations on file for this inspection.

1910.147 C07 I

Serious Gravity 5 3 instances 14 exposed
Issued
Aug 2, 2016
Abate by
Aug 26, 2016
Penalty
Initial $7,572 · Current $5,679 Reduced
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees:   (a) Production Floor - On or about May 24, 2016, machine operators, engaged in set up of the Seamers, to include cleaning the rollers and blade changes, were not trained as authorized employees in that they did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control.    (b) Production Floor - On or about May 24, 2016, all machine operators had not received training at the affected level in that they had not been instructed in the purpose and use of the energy control procedure.    (c)  Production floor - On or about May 24, 2016, all other employees whose work operations are or may be in an area where energy control procedures may be utilized, shall be instructed about the procedure, and about the prohibition relating to attempts to restart or reenergize machines or equipment which are locked out or tagged out.
Recent events (2)
  • · I (S) $5679
  • · Z (S) $7572

1910.147 D02

Serious Gravity 5 1 instance 14 exposed
Issued
Aug 2, 2016
Abate by
Aug 26, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(2): The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment:  (a) Production Floor - On or about May 24, 2016, employees engaged in set up of the Seamers, to include cleaning the rollers and blade changes, did not use the established procedures for de-energization of the machines.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.147 C06 I C

Serious Gravity 5 1 instance 14 exposed
Issued
Aug 2, 2016
Abate by
Aug 26, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i)(C): Where lockout was used for energy control, the periodic inspection did not include a review, between the inspector and each authorized employee, of that employee's responsibilities under the energy control procedure being inspected.  (a) Production Floor - On or about May 24, 2016, where energy control procedures were generally reviewed, the inspection did not include a review between the inspector and the authorized employees.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.212 A03 II

Serious Gravity 5 2 instances 4 exposed
Issued
Aug 2, 2016
Penalty
Initial $6,057 · Current $4,543 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):  (a) Production Floor - Seaming Area - On or about May 24, 2016, employee operating the Seaming Machines were exposed to hazards created by the unguarded roller nip points.  (b) Production Floor - Seaming Area - On or about May 24, 2016, an employee was exposed to hazards created by the blades on the layon roller in that the guard interlock device was inoperable.
Recent events (2)
  • · I (S) $4542.75
  • · Z (S) $6057

1910.333 A

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 2, 2016
Abate by
Aug 26, 2016
Penalty
Initial $7,572 · Current $5,679 Reduced
29 CFR 1910.333(a): Safety-related work practices were not employed to prevent electric shock or other injuries resulting from either direct or indirect electrical contacts, when work was performed near or on equipment or circuits which were or could be energized:  (a) Throughout Facility - On or about May 24, 2016, where maintenance employees work on internal electrical components of equipment which operates at 240V, the employer did not develop or implement safety-related work practices outlined in paragraphs (a) through (c) this section.
Recent events (2)
  • · I (S) $5679
  • · Z (S) $7572

1910.303 B01

Serious Gravity 10 1 instance 10 exposed
Issued
Aug 2, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees, in that the employer did not ensure the safety of the equipment pursuant to the considerations in sections (i) through (viii) of 29 CR 1910.303(b)(1):  (a) Production Area - On or about May 24, 2016, the electrical cabinet on the SL21 Sleeve Machine operating at 240V was not free from recognized hazards in that the disconnect switch was disconnected from the internal parts creating electrical hazards for employees de-energizing the equipment.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

View C-P Converters, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 341482024.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.