Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SENTRY INDUSTRIES, INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of SENTRY INDUSTRIES, INC. in 5687 NW 36TH AVE, MIAMI, FL 33142 (NAICS 325998). OSHA activity number 341485662.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Sentry Industries, INC. — free Get an email when a new federal OSHA severe-injury report for Sentry Industries, INC. is published. One employer, no account, unsubscribe in one click.
Site address
5687 NW 36TH AVE
City
MIAMI
State
FL
ZIP
33142
Mailing
5687 NW 36TH AVE, MIAMI, FL 33142
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325998
Employees
19
Ownership type
A

5 citations on file for this inspection.

1910.119 E03

Other-than-serious 1 instance 19 exposed
Issued
Aug 22, 2016
Abate by
Sep 16, 2016
Penalty
Initial $3,207 · Current $3,207

Hazardous substances 0640

29 CFR 1910.119(e)(3): The process hazard analysis did not address the elements of (i) through (vii) of this paragraph:    On or about May 19th, 2016, at the worksite located at 5687 NW 36th Ave. Miami, FL 33142, the employer did not ensure that the process hazard analysis addressed all the steps required such as, consequences of failure, engineering or administrative controls, and human factor.
Recent events (2)
  • — I (O) $3207
  • — Z (S) $3207

1910.1000 E

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 22, 2016
Abate by
Sep 16, 2016
Penalty
Initial $3,207 · Current $1,924 Reduced

Hazardous substances 0640

29 CFR 1910.1000(e): Feasible administrative or engineering controls were not determined and implemented to achieve compliance with the limits prescribed in 29 CFR 1910.1000(a) through (d):    On or about May 19th, 2016, at the worksite located at 5687 NW 36th Ave. Miami, FL 33142, the employer did not develop and implement feasible administrative controls to comply with the safety requirements for transfer connections thereby exposing employees to chorine gas production while incorrectly connecting the sodium hypochlorite railcar instead of the corresponding hydrochloric acid railcar.
Recent events (2)
  • — I (S) $1924.2
  • — Z (S) $3207

1910.132 D01 III

Other-than-serious 1 instance 1 exposed
Issued
Aug 22, 2016
Abate by
Sep 16, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.132(d)(1)(iii): The employer did not select PPE that properly fit each affected employee:  On or about May 19th, 2016, at the worksite located at 5687 NW 36th Ave. Miami, FL 33142, the employer did not ensure that the required safety equipment properly fit employees who use corrective lenses.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.134 C02 II

Other-than-serious 2 instances 5 exposed
Issued
Aug 22, 2016
Abate by
Sep 16, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user:  On or about May 19th, 2016, at the worksite located at 5687 NW 36th Ave. Miami, FL 33142, the employer did not develop and implement a written respiratory protection program for employee(s) who voluntarily wear respiratory protection such as N-95 NIOSH, Moldex N95 Model 2200 filtering facepiece respirators, and a 3M Model 6162 half mask respirator equipped with combination cartridges for inorganic gases while performing connections and emergency operations.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.134 K06

Other-than-serious 2 instances 5 exposed
Issued
Aug 22, 2016
Abate by
Sep 16, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer:  On or about May 19th, 2016, at the worksite located at 5687 NW 36th Ave. Miami, FL 33142, the employer did not provide respirator information contained in Appendix D of 29 CFR 1910.134, for employees who use N-95 NIOSH, Moldex N95 Model 2200 filtering facepiece respirators, and a 3M Model 6162 half mask respirator equipped with combination cartridges for inorganic gases while performing connections and emergency operations.