Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: O&G MASON LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of O&G MASON LLC in 464 HILLSIDE AVE, PALISADES PARK, NJ 07650 (NAICS 238140). OSHA activity number 341487114.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch O&G Mason LLC — free Get an email when a new federal OSHA severe-injury report for O&G Mason LLC is published. One employer, no account, unsubscribe in one click.
Establishment
O&G MASON LLC
Site address
464 HILLSIDE AVE
City
PALISADES PARK
State
NJ
ZIP
07650
Mailing
8106 3RD AVE. APT. 2, NORTH BERGEN, NJ 07047
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
5
Ownership type
A

4 citations on file for this inspection.

1926.451 E01

Serious Gravity 10 1 instance 4 exposed
Issued
Jul 12, 2016
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used.  Crossbraces were used as a means of access.    a) Exterior of Building - Scaffold Front: Employees were exposed to fall hazards of approximately 12 feet while engaged in masonry activities from a welded frame scaffold that did not have a proper means of access, on or about 5/16/16.
Recent events (3)
  • — F (S) $1400
  • — C (S) $2800
  • — Z (S) $2800

1926.451 F07

Serious Gravity 10 1 instance 4 exposed
Issued
Jul 12, 2016
Abate by
Jul 30, 2016
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person.    a) Exterior of Building - Scaffold Front: Employees were working on a tubular frame scaffold platform that had not been erected under the supervision of a competent person, on or about 5/16/16.
Recent events (3)
  • — F (S) $1400
  • — C (S) $2800
  • — Z (S) $2800

1926.451 G01

Serious Gravity 10 1 instance 4 exposed
Issued
Jul 12, 2016
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level.      a) Exterior of Building - Scaffold Front: Employees without proper means of fall protection, engaged in masonry activities from a welded frame scaffold platform, were exposed to fall hazards of approximately 12 feet, on or about 5/16/16.
Recent events (3)
  • — F (S) $1400
  • — C (S) $2800
  • — Z (S) $2800

1926.451 G04 II

Serious Gravity 10 1 instance 4 exposed
Issued
Jul 12, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.451(g)(4)(ii): The top edge height on all suspended scaffolds where both a guardrail and a personal fall arrest system were not between 36 inches (0.9 m) and 45 inches (1.2 m) above the platform surface:Note:  For supported scaffolds manufactured and placed in service before January 1, 2000, and on all suspended scaffolds where both a guardrail and a personal fall arrest system are required, the top edge height should be between 36 inches (0.9 m) and 45  a) Exterior of Building - Scaffold Front: Employees working from a scaffold platform with improper railing, engaged in masonry activities, were exposed to fall hazards of approximately 12 feet, on or about 5/16/16.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

View O&G Mason LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341487114.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.