Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MASTER MACHINE, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MASTER MACHINE, INC. in 10101 CHICKASAW LN, HOUSTON, TX 77041 (NAICS 332710). OSHA activity number 341488880.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Master Machine, INC. — free Get an email when a new federal OSHA severe-injury report for Master Machine, INC. is published. One employer, no account, unsubscribe in one click.
Site address
10101 CHICKASAW LN
City
HOUSTON
State
TX
ZIP
77041
Mailing
10101 CHICKASAW LN, HOUSTON, TX 77041
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332710
Employees
15
Ownership type
A

4 citations on file for this inspection.

1910.212 A01

Serious Gravity 10 6 instances 3 exposed
Issued
Jul 28, 2016
Abate by
Aug 16, 2016
Penalty
Initial $2,800 · Current $1,680 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks.  The employer does not guard all the rotating parts of machines whose operation exposes employees to injury.    a. On or about May 19, 2016, in the fabrication area where employees were exposed to struck-by and caught-by hazards when operating a Doosan PUMA 2000Y CNC machine without functioning interlocks.  b. On or about May 19, 2016, in the fabrication area where employees were exposed to struck-by and caught-by hazards when operating an Doosan PUMA 200 CNC machine without functioning interlocks.  c. On or about May 19, 2016, in the fabrication area where employees were exposed to struck-by and caught-by hazards when operating a Doosan PUMA 240 CNC machine without functioning interlocks.  d. On or about May 19, 2016, in the fabrication area where employees were exposed to struck-by and caught-by hazards when operating a Doosan PUMA 280 CNC machine without functioning interlocks.  e. On or about May 19, 2016, 2013, in the fabrication area where employees were exposed to struck-by and caught-by hazards when operating an Johnford ST40 turning center machine without functioning interlocks.  f. On or about May 19, 2016, in the fabrication area where employees were exposed to struck-by and caught-by hazards when operating an ACRA AM2V Vertical Milling Machine without a guard.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1910.242 B

Serious Gravity 1 2 instances 2 exposed
Issued
Jul 28, 2016
Abate by
Aug 9, 2016
Penalty
Initial $1,200 · Current $720 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.  On or about May 19, 2016, throughout the facility where employees were exposed to struck-by hazards while blowing off equipment using compressed air without reducing the pressure below 30 p.s.i.
Recent events (2)
  • — I (S) $720
  • — Z (S) $1200

1910.305 B01 II

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 28, 2016
Abate by
Aug 9, 2016
Penalty
Initial $2,000 · Current $1,200 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed.  On or about May 19, 2016, on an electrical panel labeled LB in the shop area where employees were exposed to electrical hazards when unused openings were not effectively closed.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $2000

1910.303 F02

Other-than-serious 1 instance 2 exposed
Issued
Jul 28, 2016
Abate by
Aug 9, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:  On or about May 19, 2016, the circuit breaker panel labeled LB had circuit breakers that were not legibly marked to indicate its purpose.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Master Machine, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341488880.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.