NEW HARTFORD, NY —
OSHA Inspection: KEVIN HUGHES CONSTRUCTION, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of KEVIN HUGHES CONSTRUCTION, INC. in HOMEWOOD SUITES, 201 WOODS PARK DRIVE, NEW HARTFORD, NY 13413 (NAICS 238130). OSHA activity number 341489276.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- KEVIN HUGHES CONSTRUCTION, INC.
- Site address
- HOMEWOOD SUITES, 201 WOODS PARK DRIVE
- City
- NEW HARTFORD
- State
- NY
- ZIP
- 13413
- Mailing
- 4 RIVERSIDE DRIVE, UTICA, NY 13502
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 12
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.304 F
- Issued
- Jul 26, 2016
- Abate by
- Aug 3, 2016
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1926.304(f) Section 4.1.2(b) American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): Circular hand-fed rip saws were not equipped with a spreader to prevent material from squeezing the saw or being thrown back on the operator: 29 CFR 1926.304(f) Section 4.1.2(c) American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): Circular hand-fed rip saws did not have non-kickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator: 29 CFR 1926.304(f) Section 5.1.3.3 American National Standards Institute 01.1-1975, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): Electrically driven equipment was not equipped with magnetic switches or other devices that will prevent automatic restarting of the machine after a power failure: a) Southwest corner of work site, on or about 5-20-16: Three employees were ripping oriented strand board (OSB) sheathing on a table saw that was not equipped with a spreader. b) Southwest corner of work site, on or about 5-20-16: Three employees were ripping oriented strand board (OSB) sheathing on a table saw that was not equipped with non kick-back fingers or dogs. c) Southwest corner of work site, on or about 5-20-16: Three employees were operating a table saw that was not equipped a magnetic switch or anti-restart device. ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM
Recent events (2)
- — I (S) $1200
- — Z (S) $2000
1926.304 I01
- Issued
- Jul 26, 2016
- Abate by
- Aug 3, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.304(i)(1): Each circular had-fed ripsaw was not guarded by a hood which completely enclosed that portion of the saw above the table and that portion of the saw above the material being cut: a) Southwest corner of work site, on or about 5-20-16: Three employees were ripping oriented strand board (OSB) sheathing on a table saw that was not equipped with a hood guard that automatically adjusts to enclose the saw blade that protrudes above the table top. ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.404 F06
- Issued
- Jul 26, 2016
- Penalty
- Initial $1,200 · Current $720 Reduced
General-duty citation text
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: a) Southwest corner of building, first floor, on or about 5-20-16: Employees were operating multiple power tools through three separate extension cords that did not have a continuous path to ground due to missing ground pins.
Recent events (2)
- — I (S) $720
- — Z (S) $1200
1926.405 G02 IV
- Issued
- Jul 26, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: a) Southwest corner of building, first floor, on or about 5-20-16: Employees were operating an electric jackhammer that was powered through an extension cord that exhibited a broken strain relief due to a torn/damaged outer sheath.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 F14
- Issued
- Jul 26, 2016
- Penalty
- Initial $1,600 · Current $960 Reduced
General-duty citation text
29 CFR 1926.451(f)(14): Makeshift devices, such as but not limited to boxes and barrels, were used on top of scaffold platforms to increase the working level height of employees: a) First floor, west side corridor, on or about 5-20-16: One employee was using blocks of wood to increase the working height of a scaffold platform.
Recent events (2)
- — I (S) $960
- — Z (S) $1600
1926.451 G01
- Issued
- Jul 26, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level: a) West side of building, on or about 5-20-16: One employee was working on a "pick" scaffold platform without fall protection, exposing the employee to a fall hazard of 12 feet 4 inches.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.501 B01
- Issued
- Jul 26, 2016
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a) West side of second floor deck, on or about 5-20-16: Three employees were installing floor sheathing at the edge of the second story floor deck and were not protected from falls, exposing the employees to a fall hazard of 14 feet 6 inches.
Recent events (2)
- — I (S) $1200
- — Z (S) $2000
More inspections at Kevin Hughes Construction, INC.
View Kevin Hughes Construction, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238130)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341489276.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.