Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,124Inspections Most recent open 2026-08-25 Last loaded 2026-08-28

OSHA Inspection: OFCO, INCORPORATED A DELAWARE CORPORATION

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of OFCO, INCORPORATED A DELAWARE CORPORATION in 111 NORTH 14TH STREET, COSHOCTON, OH 43812 (NAICS 333999). OSHA activity number 341492288.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ofco, Incorporated a Delaware Corporation for free Get an email when a new federal OSHA severe-injury report for Ofco, Incorporated a Delaware Corporation is published. One employer, no account, unsubscribe in one click.
Site address
111 NORTH 14TH STREET
City
COSHOCTON
State
OH
ZIP
43812
Mailing
P.O. BOX 218, COSHOCTON, OH 43812
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333999
Employees
56
Ownership type
Private (A)

1 citation on file for this inspection.

1910.147 C04 II

Serious Gravity 1 1 instance 5 exposed
Issued
Nov 1, 2016
Abate by
Dec 5, 2016
Penalty
Initial $4,116 · Current $4,116
29 CFR 1910.147(c)(4)(ii): The procedures did not clearly and specifically outline the rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance as required by 29 CFR 1910.147(c)(4)(ii)[C]-[D]:   a) At the workplace located at 111 North 14th Street, Coshocton, Ohio, the specific energy control procedures for the E.W. Bliss Press 3 did not contain adequate information to include, but not limited to, the following:   (1) Specific procedural steps for the placement, removal and transfer of lockout devices or tagout devices and the responsibility for them pursuant to 1910.147(c)(4)(ii)([C]. The  procedure was not specific to the location and the energy isolating device to be used, such as, but not limited to a manually operated electrical circuit breaker, disconnect switch, line valve, or any similar device used to block or isolate energy.  (2) Specific requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices and other control measures peursuant to 1910.147(c)(4(ii)[D]. The procedure lacked specific steps to verify that the air supply had been bled and made safe.
Recent events (1)
  • · Z (S) $4116

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 341492288.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.