Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: STONE BYRON MASONRY, LLC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of STONE BYRON MASONRY, LLC. in 14655 CROUCH PL, PARKER, CO 80134 (NAICS 238140). OSHA activity number 341496297.

Watch Stone Byron Masonry, LLC. — free Get an email when a new federal OSHA severe-injury report for Stone Byron Masonry, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
14655 CROUCH PL
City
PARKER
State
CO
ZIP
80134
Mailing
936 XAVIER STREET, DENVER, CO 80204
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
5
Ownership type
A

4 citations on file for this inspection.

1926.451 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1000.00 Reduced
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii):    (a) On or about May 23, 2016, Stone Byron Masonry, LLC., did not ensure that each platform on all working levels of scaffolds was fully planked or decked between the front uprights and the guardrail supports. A three-tier scaffold in use by workers was not fully planked, exposing employees to falls in excess of 15 feet.    Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1926.451 E01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1000.00 Reduced
29 CFR 1926.451(e)(1): Where scaffold platforms were more than 2 feet above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers, stairway-type ladders, ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface was not used for access:    (a) On or about May 23, 2016, Stone Byron Masonry, LLC., did not ensure that portable ladders, hook-on ladders, or other proper means of access was used to reach a scaffold platform. Workers climbed a three-tier scaffold using the side frames and the cross braces, exposing employees to falls of up to 15 feet.    Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1926.451 F03

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1500.00 Reduced
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity:    (a) On or about May 23, 2016, Stone Byron Masonry, LLC. did not ensure that scaffolds and scaffold components were inspected for visible defects by a competent person before each work shift. A three-tier scaffold in use by employees was not inspected for visible defects before each shift. Scaffold did not have properly installed guardrails, exposing employees to falls in excess of 15 feet.    Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2000

1926.451 G01 V

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(g)(1)(v): Each employee on a walkway located within a scaffold was not protected by a guardrail system (with a minimum 200 pound toprail capacity) installed within 9.5 inches (24.1 cm) of and along at least one side of the walkway:  (a) On or about May 23, 2016, Stone Byron Masonry, LLC., did not ensure that each employee on a walkway within a scaffold was protected by a guardrail system with a minimum 200 pound toprail capacity. A three-tier scaffold in use by workers did not have guardrails, exposing employees to falls in excess of 15 feet.  Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341496297.