Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: RELIABLE WELDING, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of RELIABLE WELDING, INC. in 5010 N 30TH ST, TAMPA, FL 33610 (NAICS 331221). OSHA activity number 341498939.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Reliable Welding, INC. — free Get an email when a new federal OSHA severe-injury report for Reliable Welding, INC. is published. One employer, no account, unsubscribe in one click.
Site address
5010 N 30TH ST
City
TAMPA
State
FL
ZIP
33610
Mailing
5010 N 30TH ST, TAMPA, FL 33610
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331221
Employees
5
Ownership type
A

8 citations on file for this inspection.

1910.253 B04 III

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 22, 2016
Abate by
Jun 29, 2016
Penalty
Initial $1,600 · Current $1,600
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not seperated from fuel gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire resistant rating of at least one-half hour.  a) For the facility at 5010 N 30th St., Tampa, FL 33610, as observed on or about 05/25/2016, acetylene fuel gas cylinders were stored right next to oxygen cylinders resulting in a fire hazard.
Recent events (1)
  • — Z (S) $1600

1910.215 A04

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 22, 2016
Abate by
Jul 5, 2016
Penalty
Initial $1,600 · Current $1,600
29 CFR 1910.215(a)(4): Grinding machinery was not used with work rest(s) to support offhand grinding work:  a) For the facility at 5010 N 30th St., Tampa, FL 33610, as observed on or about 05/25/2016, employees used bench grinders with tool rests either missing or not safely adjusted with gaps of 1 1/4 inches between the tool rest and the wheel periphery.
Recent events (1)
  • — Z (S) $1600

1910.215 B09

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 22, 2016
Abate by
Jun 29, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:  a) For the facility at 5010 N 30th St., Tampa, FL 33610, as observed on or about 05/25/2016, employees used a bench grinder with gaps of 2 inches measured between the abrasive wheel and the tongue guard.
Recent events (1)
  • — Z (S) $0

1910.212 A03 II

Serious Gravity 5 1 instance 4 exposed
Issued
Jun 22, 2016
Abate by
Jul 12, 2016
Penalty
Initial $2,000 · Current $2,000
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):  a) For the facility at 5010 N 30th St., Tampa, FL 33610, as observed on or about 05/25/2016, a hydraulic shear was used with part of its finger guard broken off exposing employees to amputation hazards from the hold-downs and the shear blade.
Recent events (1)
  • — Z (S) $2000

1910.253 B02 IV

Other-than-serious 1 instance 1 exposed
Issued
Jun 22, 2016
Abate by
Jun 29, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(2)(iv): Valve protection caps, where cylinders were designed to accept caps, were not always in place, hand-tight, except when cylinders were in use or connected for use:  a) For the facility at 5010 N 30th St., Tampa, FL 33610, as observed on or about 05/25/2016, acetylene cylinders were observed in the cylinder storage area (in storage) to be missing valve protection caps.
Recent events (1)
  • — Z (O) $0

1910.178 L

Other-than-serious 1 instance 2 exposed
Issued
Jun 22, 2016
Abate by
Jul 12, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l): Operators were not trained in the safe operation of powered industrial trucks:  a) For the facility at 5010 N 30th St., Tampa, FL 33610, as observed on or about 05/25/2016, forklift operators had not been trained on safe forklift operation.
Recent events (1)
  • — Z (O) $0

1910.303 B02

Other-than-serious 1 instance 4 exposed
Issued
Jun 22, 2016
Abate by
Jun 29, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  a) For the facility at 5010 N 30th St., Tampa, FL 33610, as observed on or about 05/25/2016, portable power strips were used in an industrial environment with equipment such as grinders. This condition of usage violates their UL rating.
Recent events (1)
  • — Z (O) $0

1910.147 D04 I

Other-than-serious 1 instance 1 exposed
Issued
Jun 22, 2016
Abate by
Jun 30, 2016
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:  a) For the facility at 5010 N 30th St., Tampa, FL 33610, as observed on or about 05/25/2016, maintenance was performed on a hydraulic shear and the energy isolating device was not locked out.
Recent events (1)
  • — Z (O) $0

View Reliable Welding, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341498939.