TAMPA, FL —
OSHA Inspection: RELIABLE WELDING, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of RELIABLE WELDING, INC. in 5010 N 30TH ST, TAMPA, FL 33610 (NAICS 331221). OSHA activity number 341498939.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RELIABLE WELDING, INC.
- Site address
- 5010 N 30TH ST
- City
- TAMPA
- State
- FL
- ZIP
- 33610
- Mailing
- 5010 N 30TH ST, TAMPA, FL 33610
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331221
- Employees
- 5
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.253 B04 III
- Issued
- Jun 22, 2016
- Abate by
- Jun 29, 2016
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not seperated from fuel gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire resistant rating of at least one-half hour. a) For the facility at 5010 N 30th St., Tampa, FL 33610, as observed on or about 05/25/2016, acetylene fuel gas cylinders were stored right next to oxygen cylinders resulting in a fire hazard.
Recent events (1)
- — Z (S) $1600
1910.215 A04
- Issued
- Jun 22, 2016
- Abate by
- Jul 5, 2016
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1910.215(a)(4): Grinding machinery was not used with work rest(s) to support offhand grinding work: a) For the facility at 5010 N 30th St., Tampa, FL 33610, as observed on or about 05/25/2016, employees used bench grinders with tool rests either missing or not safely adjusted with gaps of 1 1/4 inches between the tool rest and the wheel periphery.
Recent events (1)
- — Z (S) $1600
1910.215 B09
- Issued
- Jun 22, 2016
- Abate by
- Jun 29, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: a) For the facility at 5010 N 30th St., Tampa, FL 33610, as observed on or about 05/25/2016, employees used a bench grinder with gaps of 2 inches measured between the abrasive wheel and the tongue guard.
Recent events (1)
- — Z (S) $0
1910.212 A03 II
- Issued
- Jun 22, 2016
- Abate by
- Jul 12, 2016
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): a) For the facility at 5010 N 30th St., Tampa, FL 33610, as observed on or about 05/25/2016, a hydraulic shear was used with part of its finger guard broken off exposing employees to amputation hazards from the hold-downs and the shear blade.
Recent events (1)
- — Z (S) $2000
1910.253 B02 IV
- Issued
- Jun 22, 2016
- Abate by
- Jun 29, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(b)(2)(iv): Valve protection caps, where cylinders were designed to accept caps, were not always in place, hand-tight, except when cylinders were in use or connected for use: a) For the facility at 5010 N 30th St., Tampa, FL 33610, as observed on or about 05/25/2016, acetylene cylinders were observed in the cylinder storage area (in storage) to be missing valve protection caps.
Recent events (1)
- — Z (O) $0
1910.178 L
- Issued
- Jun 22, 2016
- Abate by
- Jul 12, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l): Operators were not trained in the safe operation of powered industrial trucks: a) For the facility at 5010 N 30th St., Tampa, FL 33610, as observed on or about 05/25/2016, forklift operators had not been trained on safe forklift operation.
Recent events (1)
- — Z (O) $0
1910.303 B02
- Issued
- Jun 22, 2016
- Abate by
- Jun 29, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) For the facility at 5010 N 30th St., Tampa, FL 33610, as observed on or about 05/25/2016, portable power strips were used in an industrial environment with equipment such as grinders. This condition of usage violates their UL rating.
Recent events (1)
- — Z (O) $0
1910.147 D04 I
- Issued
- Jun 22, 2016
- Abate by
- Jun 30, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: a) For the facility at 5010 N 30th St., Tampa, FL 33610, as observed on or about 05/25/2016, maintenance was performed on a hydraulic shear and the energy isolating device was not locked out.
Recent events (1)
- — Z (O) $0
More inspections at Reliable Welding, INC.
View Reliable Welding, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 331221)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341498939.