BRISTOL, CT —
OSHA Inspection: A. & D. COMPONENTS, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of A. & D. COMPONENTS, INC. in 33 STAFFORD AVENUE, BRISTOL, CT 06010 (NAICS 332613). OSHA activity number 341502243.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- A. & D. COMPONENTS, INC.
- Site address
- 33 STAFFORD AVENUE
- City
- BRISTOL
- State
- CT
- ZIP
- 06010
- Mailing
- 33 STAFFORD AVENUE, BRISTOL, CT 06010
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332613
- Employees
- 5
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.212 A01
- Issued
- Jul 7, 2016
- Abate by
- Oct 24, 2016
- Penalty
- Initial $1,200 · Current $600 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by: Tool Room: On, or about, May 23, 2016, safeguarding was not provided on the LeBlond horizontal lathe lead screw.
Recent events (2)
- — I (S) $600
- — Z (S) $1200
1910.217 B07 V A
- Issued
- Jul 7, 2016
- Abate by
- Dec 5, 2016
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.217(b)(7)(v)(a): Each two-hand control for single stroke operations on mechanical power press(es) using part revolution clutches was not protected against unintended operation: Press Area, Federal Press: On, or about, May 23, 2016, the two run buttons were not ringed or otherwise protected against unintended operation.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1910.217 B07 VIII
- Issued
- Jul 7, 2016
- Abate by
- Dec 5, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.217(b)(7)(viii): Mechanical power press(es) using part revolution clutches, with clutch/brake control systems which contained both single and continuous functions, were not designed so that in order to initiate a continuous run, a prior action or decision by the operator in addition to the selection of Continuous of the stroking selector, before the actuation of the operating means would result in continuous stroking: Press Area: On, or about, May 23, 2016, the following partial revolution mechanical power presses were not provided with either a continuous arming feature such as a control button or prolonged holding of the run buttons: A. Federal Press. B. Press #24, Minster.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.217 B07 XII
- Issued
- Jul 7, 2016
- Abate by
- Dec 5, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.217(b)(7)(xii): The clutch/brake control(s) of mechanical power press(es) with part revolution clutches did not incorporate an automatic means to prevent initiation or continued activation of the single stroke or continuous functions unless the press drive motor is energized and in the forward direction: Press Area: On, or about, May 23, 2016, Press #2, a Minster partial revolution mechanical power press, could run in the continuous mode with the motor in reverse.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.217 B12
- Issued
- Jul 7, 2016
- Abate by
- Dec 5, 2016
- Penalty
- Initial $1,200 · Current $600 Reduced
General-duty citation text
29 CFR 1910.217(b)(12): All pressure vessels used in conjunction with power presses did not conform to the American Society of Mechanical Engineers Code for Pressure Vessels, 1968 Edition: Press Room: On, or about, May 23, 2016, air tanks provided on the following partial revolution mechanical power presses did not appear to be protected by a pressure relief valve: Ref. ASME BPVC-1968, Section VIII, UG-125. A. Press #499, Minster. B. Press #24, Minster.
Recent events (2)
- — I (S) $600
- — Z (S) $1200
1910.217 C01 I
- Issued
- Jul 7, 2016
- Abate by
- Oct 24, 2016
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.217(c)(1)(i): The employer did not provide and ensure the usage of point of operation guards or properly applied point of operation devices on every operation performed on mechanical power press(es): Press Room: On, or about, May 23, 2016, the Niagara partial revolution mechanical power press was roperated without safeguarding provided in accordance with 29 CFR 1910.217.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1910.217 C02 I A
- Issued
- Jul 7, 2016
- Abate by
- Oct 24, 2016
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.217(c)(2)(i)(a): Point of operation guard(s) on mechanical power press(es) did not prevent entry of hands or fingers into the point of operation by reaching through, over, under or around the guard(s): Press Room: On, or about, May 23, 2016, the barrier guards provided on the following mechanical power presses allowed access to the point of operation by reaching over and/or around the guard: A. Press #2, Minster. B. Federal Press. C. Press #24, Minster.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1910.217 E01 I
- Issued
- Jul 7, 2016
- Abate by
- Oct 24, 2016
- Penalty
- Initial $1,200 · Current $600 Reduced
General-duty citation text
29 CFR 1910.217(e)(1)(i): A program of periodic and regular inspections of mechanical power press(es) was not established and followed to ensure that all parts, auxiliary equipment and safeguards were in a safe operating condition and adjustment: Company: On, or about, May 23, 2016, the company had not developed a program of periodic inspections on mechanical power presses.
Recent events (2)
- — I (S) $600
- — Z (S) $1200
1910.219 B01
- Issued
- Jul 7, 2016
- Abate by
- Oct 24, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(b)(1): Flywheel(s) with parts seven feet or less above floor(s) or platform(s) were not guarded in accordance with the requirements specified in 29 CFR 1910.219(b)(1)(i) through (b)(1)(iv): Press Room: On, or about, May 23, 1961, the flywheel guard provided on the Federal Press did not cover the rotating flywheel near the operators station.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at A. & D. Components, INC.
View A. & D. Components, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332613)
More inspections in CT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341502243.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.