Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BENCHMARK FOAM, INC.

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of BENCHMARK FOAM, INC. in 401 PHEASANT RIDGE DRIVE, WATERTOWN, SD 57201 (NAICS 325211). OSHA activity number 341505980.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Benchmark Foam, INC. — free Get an email when a new federal OSHA severe-injury report for Benchmark Foam, INC. is published. One employer, no account, unsubscribe in one click.
Site address
401 PHEASANT RIDGE DRIVE
City
WATERTOWN
State
SD
ZIP
57201
Mailing
401 PHEASANT RIDGE DRIVE, WATERTOWN, SD 57201
Inspection type
Federal Agency (M)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325211
Employees
78
Ownership type
A

2 citations on file for this inspection.

1910.303 A

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 26, 2016
Abate by
Oct 21, 2016
Penalty
Initial $8,730 · Current $12,471
29 CFR 1910.303(a): The conductors and/or equipment required or permitted by this subpart were not approved:    (a)Benchmark Foam, Inc. @ 401 Pheasant Ridge Drive, Watertown, SD 57201: On and prior to May 20, 2016, the employer did not ensure that the shop-made hot wire cutter used to cut excess expanded polystyrene foam was approved, certified, listed or labeled or otherwise determined to be safe by a nationally recognized testing laboratory. The wooden paddles of the hot wire cutter were designed and constructed within the facility to be held by employees to cut excess foam off of newly molded polystyrene foam blocks. In the event the mold was opened prematurely and post expansion occurred, the hot wire cutter was used by employees to cut away excess expanded foam to allow the mold to close.  The wooden handles of the hot wire cutter had exposed, non-insulated electrical connections where employees held the cutter, thus exposing employees to live parts. On May 20, 2016, an employee utilizing the hot wire cutter to cut excess polystyrene foam came into direct contact with the electrical connections on the wooden handle of the cutting tool and was electrocuted. This condition exposed employees using the hot wire cutter to the hazard of electrical burns, shock and electrocution hazards.     Abatement Note: Under �1910.399, "the Assistant Secretary will deem an installation or equipment "acceptable" if it is "accepted, or certified, or listed, or labeled, or otherwise determined to be safe by a [NRTL] recognized pursuant to �1910.7." And with respect to installations or equipment that no NRTL "accepts, certifies, lists, labels, or determines to be safe," the Assistant Secretary will deem such equipment or installations "acceptable" if they are "inspected or tested by another Federal agency, or by a State, municipal, or other local authority responsible for enforcing occupational safety provisions of the National Electrical Code, and found in compliance with the provisions of the National Electrical Code as applied in" Subpart S.
Recent events (2)
  • — I (S) $12471
  • — Z (S) $8730

1910.303 B01

Serious Gravity 10 1 instance 1 exposed
Issued
Sep 26, 2016
Abate by
Oct 21, 2016
Penalty
Initial $8,730 · Current $0 Reduced
29 CFR 1910.303(b)(1):  Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees:     (a)Benchmark Foam, Inc. @ 401 Pheasant Ridge Drive, Watertown, SD 57201: On and prior to May 20, 2016, the employer did not ensure that the hot wire cutter used to cut excess expanded polystyrene foam was free from recognized hazards. The hot wire cutter was designed and constructed within the facility to cut excess foam off of newly created polystyrene foam blocks being manufactured. In the event the block mold was opened prematurely and post expansion occurred, the hot wire cutter was used by employees to cut away excess expanded foam to allow the mold to close.  The wooden paddles of the hot wire cutter had exposed non-insulated electrical connections where employees held the cutter, thus exposing employees to live parts. On May 20, 2016, an employee utilizing the hot wire cutter to cut excess polystyrene foam came into direct contact with the energized electrical connections on the wooden handle of the cutting tool and was electrocuted. This condition exposed the employees to the hazard of electrical burns, shock and electrocution hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $8730

View Benchmark Foam, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341505980.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.