Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,871Inspections Most recent open 2026-07-30 Last loaded 2026-08-03

OSHA Inspection: FREDDY ESPANA

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of FREDDY ESPANA in 1016 ELLSWORTH STREET, PHILADELPHIA, PA 19147 (NAICS 238140). OSHA activity number 341506046.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Freddy Espana for free Get an email when a new federal OSHA severe-injury report for Freddy Espana is published. One employer, no account, unsubscribe in one click.
Establishment
FREDDY ESPANA
Site address
1016 ELLSWORTH STREET
City
PHILADELPHIA
State
PA
ZIP
19147
Mailing
1701 SOUTH 19TH STREET, PHILADELPHIA, PA 19145
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
4
Ownership type
A

6 citations on file for this inspection.

1926.451 B01

Serious Gravity 10 1 instance 3 exposed
Issued
Nov 17, 2016
Abate by
Nov 23, 2016
Penalty
Initial $4,988 · Current $4,988
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports.  a) Jobsite - The employer did not ensure that all working levels of the supported tubular welded frame scaffold were fully planked or decked between the front uprights and the guardrail supports.  Employees were performing stucco operations from the 2nd and 3rd working platforms, approximately 15 and 21 feet above ground level.   Noted on or about 5/25/16.
Recent events (1)
  • · Z (S) $4988

1926.451 C02 II

Serious Gravity 5 1 instance 3 exposed
Issued
Nov 17, 2016
Abate by
Nov 23, 2016
Penalty
Initial $3,563 · Current $3,563
29 CFR 1926.451(c)(2)(ii): Unstable objects were used to support scaffolds or platform units.  a) Jobsite: - Employees conducting masonry operations from the supported tubular welded frame scaffold were exposed to shift, dislocation, and tip over hazards as the employer used hollow core concrete blocks to support the base of the scaffold.  Noted on or about 5/25/16.
Recent events (1)
  • · Z (S) $3563

1926.451 E01

Serious Gravity 5 1 instance 3 exposed
Issued
Nov 17, 2016
Abate by
Nov 23, 2016
Penalty
Initial $3,563 · Current $3,563
29 CFR 1926.451(e)(1): A means of access for scaffold platforms more than 2 feet (0.6 m) above or below a point of access, such as portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface was not used.   a) Jobsite: Employees conducting masonry operations from a supported tubular welded frame scaffold, from platforms approximately 15 and 21 feet above ground level, were not provided with a safe means of access with the use of portable ladders, hook-on ladders or other acceptable means. Employees were observed climbing down using the rungs of the integral prefabricated access scaffold end frames.   Observed on or about 5/25/16.
Recent events (1)
  • · Z (S) $3563

1926.451 F06

Serious Gravity 10 1 instance 3 exposed
Issued
Nov 17, 2016
Abate by
Nov 23, 2016
Penalty
Initial $4,988 · Current $4,988
29 CFR 1926.451(f)(6): Scaffolds were erected, used, dismantled, altered, or moved such that they or any conductive material handled on them might come closer than 10 ft. to power lines.  a) Jobsite: The right and left sides of the supported tubular welded frame scaffold were erected within 2 feet of unguarded electrical wires exposing employees conducting masonry operations in proximity to the wires to electrical shock hazards.   Noted on or about 5/25/16.
Recent events (1)
  • · Z (S) $4988

1926.451 G01 VII

Serious Gravity 10 1 instance 3 exposed
Issued
Nov 17, 2016
Abate by
Nov 23, 2016
Penalty
Initial $4,988 · Current $4,988
29 CFR 1926.451(g)(1)(vii): For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee was not protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.  a) Jobsite: Employees conducting masonry operations from the supported tubular welded frame scaffold were exposed to fall hazards, approximately 15 and 21 feet above ground level, without the use of a fall protection system.  Noted on or about 5/25/16.
Recent events (1)
  • · Z (S) $4988

1926.454 A

Serious Gravity 5 1 instance 3 exposed
Issued
Nov 17, 2016
Abate by
Dec 7, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.454(a): The employer did not have each employee who performed work on a scaffold be trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used, and to understand the procedures to control or minimize those hazards.  a) Jobsite: The employer did not train their employees to recognize the hazards that are present when working from a supported tubular welded frame scaffold, and to understand the procedures to control or minimize those hazards.  Noted on or about 5/25/16.
Recent events (1)
  • · Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341506046.