Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,201Inspections Most recent open 2026-08-31 Last loaded 2026-09-03

OSHA Inspection: AAA QUALITY HOME CARE

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of AAA QUALITY HOME CARE in 881 RICHMOND AVENUE, BUFFALO, NY 14222 (NAICS 238160). OSHA activity number 341523322.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch AAA Quality Home Care for free Get an email when a new federal OSHA severe-injury report for AAA Quality Home Care is published. One employer, no account, unsubscribe in one click.
Site address
881 RICHMOND AVENUE
City
BUFFALO
State
NY
ZIP
14222
Mailing
1098 BASELINE ROAD, GRAND ISLAND, NY 14072
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
7
Ownership type
Private (A)

3 citations on file for this inspection.

1926.451 G01 I

Serious Gravity 10 1 instance 3 exposed
Issued
Jun 10, 2016
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system:   a) On or about 06/03/16, on the south side of a house at 881 Richmond Ave., Buffalo, NY: Employees were on the pik of a ladder jack scaffold while engaged in transporting roofing materials and accessing the roof. The employees were exposed to a fall of approx. 20 ft. to the ground.  No personal fall arrest system or other fall protection system was utilized.     NO ABATEMENT DOCUMENTATION REQUIRED
Recent events (1)
  • · Z (S) $2800

1926.1053 B01

Serious Gravity 10 2 instances 5 exposed
Issued
Jun 10, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:   a) On or about 06/03/16, on the south side of a house at 881 Richmond Ave., Buffalo, NY: A ladder jack scaffold was erected on the south side of the house.  Employees used an extension ladder to access the pik of the scaffold. The employees were exposed to a fall of approx. 19 ft. to the ground because the siderails of an extension ladder used to access the scaffold from the ground only extended approx. 30 inches above the pik.    b) On or about 06/03/16, on the north side of a house at 881 Richmond Ave., Buffalo, NY:  An extension ladder was erected at the northwest corner of the roof.  Employees used the extension ladder to access the north roof on the house.  The employees were exposed to a fall of approx.  21 ft. to the ground because the right siderail of the extension ladder only extended approx. 6 inches above the edge of the roof,  and the left siderail of the extension ladder only extended approx.  20 inches above the edge of the roof.    NO ABATEMENT DOCUMENTATION REQUIRED
Recent events (1)
  • · Z (S) $0

1926.501 B11

Serious Gravity 10 1 instance 5 exposed
Issued
Jun 10, 2016
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toe boards, safety net systems, or personal fall arrest systems:   a) On or about 06/03/16, on the south side of the roof of a house at 881 Richmond Ave., Buffalo, NY:  Three employees engaged in roofing off work on a steep roof were exposed to a fall of approx. 20 foot. No fall protection system was provided or utilized. Pitch of the roof was 12 in 12.   NO ABATEMENT DOCUMENTATION REQUIRED