PUEBLO, CO ·
OSHA Inspection: TRINITY PLASTICS INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of TRINITY PLASTICS INC. in 33500 LOCKHEED AVE., PUEBLO, CO 81001 (NAICS 326111). OSHA activity number 341523926.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TRINITY PLASTICS INC.
- Site address
- 33500 LOCKHEED AVE.
- City
- PUEBLO
- State
- CO
- ZIP
- 81001
- Mailing
- 33500 LOCKHEED AVE., PUEBLO, CO 81001
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326111
- Employees
- 60
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1910.212 A01
- Issued
- Jun 13, 2016
- Abate by
- Jun 30, 2016
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) On or about May 31, 2016, the employer did not ensure the door latches on the Dual Wichter machine, which prevents access to the machine point of operation was affixed so that it could not be easily opened. Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- · I (S) $1400
- · Z (S) $2800
1910.219 C04 I
- Issued
- Jun 13, 2016
- Abate by
- Jun 30, 2016
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) did not present a smooth edge and end and projected more than one half the diameter of the shaft: (a) On or about May 31, 2016, the employer did not ensure that the three press machines shaft ends where the ink is distributed were guarded. The shaft ends on the press machines were measured at two and one half inch in length and the diameter was approximately one inch. Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- · I (S) $1400
- · Z (S) $2800
1910.305 B02 I
- Issued
- Jun 13, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy: (a) On or about May 31, 2016, the employer exposed employees to an electrical hazards due to missing electrical faceplate. The faceplate cover in the administration office was missing and an electrical heater was plugged into the electrical outlet. Abatement Note: Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections at Trinity Plastics INC.
View Trinity Plastics INC.'s full OSHA safety record →
More inspections in this industry (NAICS 326111)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 341523926.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.