Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ACUITY BRANDS LIGHTING, INC

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of ACUITY BRANDS LIGHTING, INC in 3 KILMER RD., EDISON, NJ 08817 (NAICS 335122). OSHA activity number 341526101.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Acuity Brands Lighting, INC — free Get an email when a new federal OSHA severe-injury report for Acuity Brands Lighting, INC is published. One employer, no account, unsubscribe in one click.
Site address
3 KILMER RD.
City
EDISON
State
NJ
ZIP
08817
Mailing
1400 LETER ROAD, CONYERS, GA 30012
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
335122
Employees
223
Ownership type
A

2 citations on file for this inspection.

1910.134 E01

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 25, 2016
Abate by
Dec 30, 2016
Penalty
Initial $7,126 · Current $4,276 Reduced
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator before the employee was fit tested or required to use the respirator in the workplace:          Acuity Brands Lighting, Inc./ NJ site: Medical evaluations were not completed for all employees required to wear respirators during powdercoating operation.       Condition observed on/or about 06/02/2016.
Recent events (3)
  • — R (S) $4275.6
  • — C (S) $7126
  • — Z (S) $7126

1910.1200 H01

Serious Gravity 5 1 instance 4 exposed
Issued
Nov 25, 2016
Abate by
Dec 30, 2016
Penalty
Initial $7,126 · Current $4,276 Reduced
29 CFR 1910.1200(h)(1): Employers were not provided information and training as specified in 29 CFR 1910.1200(h)(2) and (3) on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard was introduced into their work area:            Acuity Brands Lighting, Inc./ NJ site: Employees did not receive hazard communication  training for products such as Low cure Twinkle White 3648M to identify health risks associated with its use during powder coating operations.       Condition observed on/or about 06/02/2016.
Recent events (3)
  • — R (S) $4275.6
  • — C (S) $7126
  • — Z (S) $7126

View Acuity Brands Lighting, INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341526101.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.