FORT LAUDERDALE, FL ·
OSHA Inspection: AA PROFESSIONAL TILE AND MARBLE. INC, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of AA PROFESSIONAL TILE AND MARBLE. INC, INC. in 3200 S. UNIVERSITY DR., FORT LAUDERDALE, FL 33328 (NAICS 236116). OSHA activity number 341527224.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AA PROFESSIONAL TILE AND MARBLE. INC, INC.
- Site address
- 3200 S. UNIVERSITY DR.
- City
- FORT LAUDERDALE
- State
- FL
- ZIP
- 33328
- Mailing
- 6427 SW 15TH ST, MIAMI, FL 33144
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236116
- Employees
- 4
- Ownership type
- Private (A)
Citations
6 citations on file for this inspection.
1926.55 A
- Issued
- Aug 1, 2016
- Abate by
- Aug 5, 2016
- Penalty
- Initial $2,800 · Current $1,680 Reduced
9010
General-duty citation text
29 CFR 1926.55(a): Employee(s) were exposed to material(s) at concentrations above those specified in the Threshold Limit Values of Airborne Contaminants for 1970 of the American Conference of Governmental Industrial Hygienists: On or about June 7th, 2016, at the jobsite located at 3200 S University Dr. Fort Lauderdale, FL 33328: a. An employee driving a ride-on scrapper vehicle with the purpose of removing tiles over concrete, was over-exposed to respirable silica dust at a concentration of 2.87 mg/m3 (equivalent to 28.71 mppcf) expressed as an 8 hour time-weighted average of 2.18 times the daily Permissible Exposure Limit (PEL) of 1.23 mg/m3 (equivalent to 12.25 mppcf) based on a 395 minute sampling period; exposure calculations included a zero increment for the 85 minutes not sampled. b. An employee engaged in sweeping the debris and dust produced by the scrapper, was over-exposed to respirable silica dust at a concentration of 2.6 mg/m3 (equivalent to 26.03 mppcf) expressed as an 8 hour time-weighted average of 1.99 times the daily Permissible Exposure Limit (PEL) of 1.21 mg/m3 (equivalent to 12.09 mppcf) based on a 390 minute sampling period; exposure calculations included a zero increment for the 90 minutes not sampled.
Recent events (2)
- · I (S) $1680
- · Z (S) $2800
1926.55 B
- Issued
- Aug 1, 2016
- Abate by
- Aug 5, 2016
- Penalty
- Initial $0 · Current $0
9010
General-duty citation text
29 CFR 1926.55(b): When administrative or engineering controls were not feasible to achieve full compliance, protective equipment or other protective measures were not used to keep the exposure of employees to air contaminants within the limits prescribed by 29 CFR 1926.55: On or about June 7th, 2016, at the jobsite located at 3200 S University Dr. Fort Lauderdale, FL 33328, the employer did not implanted feasible administrative or engineering controls for: a. An employee driving a ride-on scrapper vehicle with the purpose of removing tiles over concrete, was over-exposed to respirable silica dust at a concentration of 2.87 mg/m3 (equivalent to 28.71 mppcf) expressed as an 8 hour time-weighted average of 2.18 times the daily Permissible Exposure Limit (PEL) of 1.23 mg/m3 (equivalent to 12.25 mppcf) based on a 395 minute sampling period; exposure calculations included a zero increment for the 85 minutes not sampled. b. An employee engaged in sweeping the debris and dust produced by the scrapper, was over-exposed to respirable silica dust at a concentration of 2.6 mg/m3 (equivalent to 26.03 mppcf) expressed as an 8 hour time-weighted average of 1.99 times the daily Permissible Exposure Limit (PEL) of 1.21 mg/m3 (equivalent to 12.09 mppcf) based on a 390 minute sampling period; exposure calculations included a zero increment for the 90 minutes not sampled.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.134 C01
- Issued
- Aug 1, 2016
- Abate by
- Aug 25, 2016
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: (Construction Reference 1926.103) On or about June 7th, 2016, at the jobsite located at 3200 S University Dr. Fort Lauderdale, FL 33328, the employer did not develop and implement a respiratory protection program for employees who are required to wear a filtering facepiece air purifying respirator 3M, N95 Model 8210 and a tight fitting respirator 3M Model 7502.
Recent events (2)
- · I (S) $1680
- · Z (S) $2800
1910.134 E01
- Issued
- Aug 1, 2016
- Abate by
- Aug 25, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: (Construction Reference 1926.103). On or about June 7th, 2016, at the jobsite located at 3200 S University Dr. Fort Lauderdale, FL 33328, the employer did not provide a medical evaluation to determine the employee's ability to use a respirator for employees who are required to wear a filtering facepiece air purifying respirator 3M, N95 Model 8210 and a tight fitting respirator 3M Model 7502.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.134 F02
- Issued
- Aug 1, 2016
- Abate by
- Aug 25, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(2): Employee(s) using a tight-fitting facepiece respirator were not annually fit tested: (Construction Reference 1926.103). On or about June 7th, 2016, at the jobsite located at 3200 S University Dr. Fort Lauderdale, FL 33328, the employer did not provide a fit-test prior to having employees wear a filtering facepiece air purifying respirator.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.1200 E01
- Issued
- Aug 1, 2016
- Abate by
- Aug 25, 2016
- Penalty
- Initial $2,800 · Current $1,680 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: (Construction Reference: 1926.59) On or about June 7th, 2016, at the jobsite located at 3200 S University Dr. Fort Lauderdale, FL 33328, the employer did not develop and implement a written hazard communication program for employees exposed to chemical hazards such as, but not limited to, silica.
Recent events (2)
- · I (S) $1680
- · Z (S) $2800
More inspections in this industry (NAICS 236116)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 341527224.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.