LORAIN, OH —
OSHA Inspection: TERMINAL READY MIX, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of TERMINAL READY MIX, INC. in 524 COLORADO AVE., LORAIN, OH 44052 (NAICS 327320). OSHA activity number 341534006.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TERMINAL READY MIX, INC.
- Site address
- 524 COLORADO AVE.
- City
- LORAIN
- State
- OH
- ZIP
- 44052
- Mailing
- 524 COLORADO AVE., LORAIN, OH 44052
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327320
- Employees
- 50
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.146 C01
- Issued
- Sep 15, 2016
- Abate by
- Oct 11, 2016
- Penalty
- Initial $6,236 · Current $3,115 Reduced
General-duty citation text
29 CFR 1910.146(c)(1): The employer did not evaluate the workplace to determine if any spaces were permit-required confined spaces: a.) Terminal Ready Mix, Inc. located at 524 Colorado Ave. Lorain, OH; On or about May 8, 2016, the employer did not ensure the workplace was evaluated to determine if any spaces were permit-required confined spaces. Employees are required to enter the plant cement mixer to replace the liner and are exposed to hazards associated with the rotating drum and welding fumes.
Recent events (2)
- — I (S) $3115
- — Z (S) $6236
1910.146 D03
- Issued
- Sep 15, 2016
- Abate by
- Oct 11, 2016
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.146(d)(3): Under the permit-required confined space program required by 29 CFR 1910.146(c)(4), the employer did not develop and implement the means, procedures, and practices necessary for safe permit space entry operations; a.) Terminal Ready Mix, Inc. located at 524 Colorado Ave. Lorain, OH; On or about May 8, 2016, the employer did not ensure the permit required confined space program was implemented prior to employees entering the 12 Yard Plant Cement Mixer. Employees are required to enter the plant mixer to chip out and replace the polyurethane liners and did not perform air monitoring or lock out the mixer prior to entry.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.146 G01
- Issued
- Sep 15, 2016
- Abate by
- Oct 11, 2016
- Penalty
- Initial $6,236 · Current $3,115 Reduced
General-duty citation text
29 CFR 1910.146(g)(1): The employer did not provide training so that all employees whose work was regulated by 29 CFR 1910.146 (permit required confined spaces) acquired the understanding, knowledge, and skills necessary for the safe performance of the duties assigned under 29 CFR 1910.146: a.) Terminal Ready Mix, Inc. located at 524 Colorado Ave. Lorain, OH; On or about May 8, 2016, the employer did not ensure each employee required to enter a permit required confined space was trained with the knowledge and skills necessary to safely perform entry of a permit required confined space. Employees were not trained in required permit documentation measures, that atmospheric testing was needed when entering and while in the cement mixer, and the need to have an attendant outside the pace to help the entrant in an emergency situation. Employees are exposed to hazards from the rotating mixer and hazards associated with welding fumes.
Recent events (2)
- — I (S) $3115
- — Z (S) $6236
1910.147 C01
- Issued
- Sep 15, 2016
- Abate by
- Oct 11, 2016
- Penalty
- Initial $6,236 · Current $3,115 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: a.) Terminal Ready Mix, Inc. located at 524 Colorado Ave. Lorain, OH; On or about May 8, 2016, the employer did not ensure an energy control program, consisting of energy control procedures, training and periodic inspections was provided to employees. Employees are required to perform maintenance on the 12 yard Plant Cement Mixer and remove guarding on the dust collector motor, and do not properly deenergize the equipment, exposing employees to struck by and caught-in hazards.
Recent events (2)
- — I (S) $3115
- — Z (S) $6236
1910.212 A01
- Issued
- Sep 15, 2016
- Abate by
- Oct 11, 2016
- Penalty
- Initial $8,730 · Current $4,365 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a.) Terminal Ready Mix, Inc. located at 524 Colorado Ave. Lorain, OH; On May 13, 2016, the employer did not ensure the guard on the Dust Collector motor was not easily removed. An employee removed the cover to find grease fittings that had fallen when his hand was caught between a belt and two pulleys, resulting in an amputation of the tip of the right index finger.
Recent events (2)
- — I (S) $4365
- — Z (S) $8730
1910.332 B01
- Issued
- Sep 15, 2016
- Abate by
- Oct 11, 2016
- Penalty
- Initial $6,236 · Current $3,115 Reduced
General-duty citation text
29 CFR 1910.332(b)(1): Employees were not trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertained to their respective job assignments: a.) Terminal Ready Mix, Inc. located at 524 Colorado Ave. Lorain, OH; On or about May 8, 2016, the employer did not ensure employees were trained in and familiar with electrical safety related work practices before pulling 480V fuses on the Plant Cement Mixer. Employees were required to pull fuses before performing maintenance on the 480V mixer and did not have any training on Electrical Safety Related Work Practices.
Recent events (2)
- — I (S) $3115
- — Z (S) $6236
1910.333 A
- Issued
- Sep 15, 2016
- Abate by
- Oct 11, 2016
- Penalty
- Initial $6,236 · Current $0 Reduced
General-duty citation text
29 CFR 1910.333(a): Safety-related work practices were not employed to prevent electric shock or other injuries resulting from either direct or indirect electrical contacts, when work was performed near or on equipment or circuits which were or could be energized: a.) Terminal Ready Mix, Inc. located at 524 Colorado Ave. Lorain, OH; On or about May 8, 2016, the employer did not ensure employees utilized electrical safety related work practices while pulling 480V fuses on the Plant Cement Mixer. Employees were required to perform work on the Plant Cement Mixer and pulled the 480V fuses to ensure energy control and were exposed to electric shock and arc flash hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $6236
1910.335 A01
- Issued
- Sep 15, 2016
- Abate by
- Oct 11, 2016
- Penalty
- Initial $6,236 · Current $3,115 Reduced
General-duty citation text
29 CFR 1910.335(a)(1): Employees working in areas where there were potential electrical hazards were not provided with, and/or did not use, electrical protective equipment that was appropriate for the specific parts of the body to be protected and for the work to be performed: a.) Terminal Ready Mix, Inc. located at 524 Colorado Ave. Lorain, OH; On or about May 8, 2016, the employer did not ensure employees were protected while pulling six 480V fuses on the 12 yard Plant Cement Mixer. Employees are required to pull the fuses on the mixer, and did not verify zero energy with a meter, before performing work and did not wear the required face, eye, hand, and body protection, exposing them to electrical shock and arc flash hazards when pulling the fuses with fuse pullers.
Recent events (2)
- — I (S) $3115
- — Z (S) $6236
1904.39 A02
- Issued
- Sep 15, 2016
- Penalty
- Initial $3,500 · Current $1,760 Reduced
General-duty citation text
29 CFR 1904.39(a)(2): The employer failed to report the in-patient hospitalization of one or more employees or an employee's amputation or an employee's loss of an eye, as a result of a work-related incident, within (24) twenty-four hours: a.) Terminal Ready Mix located at 524 Colorado Ave. Lorain, OH 44052; On or about June 8, 2016, the employer did not ensure an amputation injury was reported to the local OSHA office within 24 hours. An amputation injury occurred on May 13, 2016, and was not reported until June 6, 2016.
Recent events (2)
- — I (O) $1760
- — Z (O) $3500
More inspections at Terminal Ready MIX, INC.
View Terminal Ready MIX, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 327320)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341534006.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.