Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,288Inspections Most recent open 2026-07-24 Last loaded 2026-07-29

OSHA Inspection: JOSE LUIS GARCIA

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JOSE LUIS GARCIA in 1620 CORNERSTONE WAY, ALPHARETTA, GA 30009 (NAICS 238170). OSHA activity number 341537512.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Jose Luis Garcia — free Get an email when a new federal OSHA severe-injury report for Jose Luis Garcia is published. One employer, no account, unsubscribe in one click.
Establishment
JOSE LUIS GARCIA
Site address
1620 CORNERSTONE WAY
City
ALPHARETTA
State
GA
ZIP
30009
Mailing
330 WINDSOR BROOK LANE, LAWRENCEVILLE, GA 30045
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
7
Ownership type
A

4 citations on file for this inspection.

1926.403 B02

Serious Gravity 5 1 instance 1 exposed
Issued
Aug 25, 2016
Penalty
Initial $2,352 · Current $2,000 Reduced
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification:    (a) New residential construction on Lot #93, South side: On or about June 9, 2016, and at times prior, the employer exposed employees to electrical shock hazards while using an electrical junction box connected to an extension cord, in that the makeshift power strip/junction box is intended for indoor use and is manufactured to be fixed to a support within a structure.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $2352

1926.1052 C01 II

Serious Gravity 5 1 instance 3 exposed
Issued
Aug 25, 2016
Penalty
Initial $2,352 · Current $2,000 Reduced
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stairrail system along each unprotected side or edge:    (a) New residential construction lot #93, First floor stairway: On or about June 9 2016, and at times prior, the employer exposed employees to fall hazards up to 4-feet, 6-inches on a stairway, in that stair rails were not provided on a stairway which was 8 risers high and 4-feet, 6-inches from the lower level from the first floor to the landing leading toward the second level.
Recent events (2)
  • — I (S) $2000
  • — Z (S) $2352

1926.451 G01 VII

Repeat Gravity 10 1 instance 2 exposed
Issued
Aug 25, 2016
Penalty
Initial $8,231 · Current $5,060 Reduced
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section:    (a) New residential construction on Lot #93, South side: On or about June 6, 2016, and times prior, the employer exposed employees to fall hazards of 24-feet, 2-inches from the pump jack scaffold platform, in that fall arrest was not provided to employees while installing cornice boards.       Garcia's, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29CFR 1926.501(g)(1), which was contained in OSHA inspection number 1043416, citation number 1, item number 2 and was affirmed as a final order on 03/30/2015, with respect to a workplace located at 1805 Dearborne Lane, Alpharetta, GA 30009.
Recent events (2)
  • — I (R) $5060
  • — Z (R) $8231

1926.403 B01

Other-than-serious 1 instance 2 exposed
Issued
Aug 25, 2016
Penalty
Initial $0 · Current $0
29 CFR 1926.403(b)(1): Employer did not ensure that electrical equipment is free from recognized hazards that are likely to cause death or serious physical harm to employees:  (a) New residential construction, South side: On or about June 9, 2016, and at times prior, the employer failed to inspect all of the electrical cords prior to the start of the work shift. Extension cords used to power circular saws had torn outer casing, missing ground pins and not removed from service.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Jose Luis Garcia's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341537512.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.